Your browser doesn't support javascript.
loading
Utilidad de la ecocardiografía omniplanar transesofßgica de stress con dobutamina en la detección de cardiopatÝa isquÚmica / Usefulness of transesophageal dobutamine stress echocardiography in the detection of ischemic cardiopathy
Azpiri-López, José Ramón; Assad-Morell, José Luis; Hoyos-Pescador, Roxana; Loera-Torres, Javier; Flores-Coronado, Evangelina.
Afiliação
  • Azpiri-López, José Ramón; Hospital Christus Muguerza de Monterrey. Monterrey. MX
  • Assad-Morell, José Luis; Hospital Christus Muguerza de Monterrey. Monterrey. MX
  • Hoyos-Pescador, Roxana; Hospital Christus Muguerza de Monterrey. Monterrey. MX
  • Loera-Torres, Javier; Hospital Christus Muguerza de Monterrey. Monterrey. MX
  • Flores-Coronado, Evangelina; Hospital Christus Muguerza de Monterrey. Monterrey. MX
Arch. cardiol. Méx ; 72(2): 105-114, abr.-jun. 2002.
Article em Es | LILACS | ID: lil-329840
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVE:

To assess the usefulness of transesophageal dobutamine stress echocardiography (TEDSE), to identify patients with coronary artery disease.

METHODS:

Patients referred for TEDSE with coronary angiography were included. Images were digitized in systolic cine-loop at baseline, with low dose-dobutamine (14.4 +/- 5 micrograms/kg/min), with high dose-dobutamine (28.7 +/- 10.5 micrograms/kg/min) and during recovery, and then analyzed by two observers. The left ventricle was divided into 16 segments according to coronary distribution, and the study was considered abnormal if there was a new or worsening of the segmental wall motion abnormality. Quantitative coronary angiographies were independently assessed, and lesions considered significant if they had > or = 70 diameter stenosis.

RESULTS:

Sixty eight patients were included. TEDSE sensitivity, specificity, and accuracy were 93, 89.7, and 91.1, respectively. TEDSE correctly detected 7/7 single vessel disease and 20/22 multiple vessel disease patients. Twelve-lead ECG had a sensitivity, specificity, and accuracy of 38.3, 91.8, and 74.5 respectively, to detect the same lesions.

CONCLUSIONS:

TEDSE is feasible, safe, sensitive, and specific to detect significant coronary lesions. It should be considered in patients with suboptimal acoustic window or poor visualization of endocardial borders.
Assuntos
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Simpatomiméticos / Isquemia Miocárdica / Ecocardiografia Transesofagiana / Dobutamina / Cardiopatias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male Idioma: Es Revista: Arch. cardiol. Méx Assunto da revista: CARDIOLOGIA Ano de publicação: 2002 Tipo de documento: Article País de afiliação: México País de publicação: México
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Simpatomiméticos / Isquemia Miocárdica / Ecocardiografia Transesofagiana / Dobutamina / Cardiopatias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male Idioma: Es Revista: Arch. cardiol. Méx Assunto da revista: CARDIOLOGIA Ano de publicação: 2002 Tipo de documento: Article País de afiliação: México País de publicação: México