Your browser doesn't support javascript.
loading
1, 5-anhydroglucitol levels in type 2 diabetic and non-diabetic subjects in southern Taiwan
Chih-Chen, Lu; Hing-Chung, Lam; Chih-Hsun, Chu; Ming-Ju, Chaung; Mei-Chun, Wang; Jenn-Kuen, Lee.
Afiliação
  • Chih-Chen, Lu; National Yang Ming University. School of Medicine. Department of Medicine. CN
  • Hing-Chung, Lam; National Yang Ming University. School of Medicine. Department of Medicine. CN
  • Chih-Hsun, Chu; National Yang Ming University. School of Medicine. Department of Medicine. CN
  • Ming-Ju, Chaung; Veterans General Hospital-Kaohsiung. CN
  • Mei-Chun, Wang; Veterans General Hospital-Kaohsiung. CN
  • Jenn-Kuen, Lee; National Yang Ming University. School of Medicine. Department of Medicine. CN
Arq. bras. endocrinol. metab ; 47(6): 711-715, dez. 2003. tab
Article em En | LILACS | ID: lil-356035
Biblioteca responsável: BR1.2
RESUMO

PURPOSES:

To estimate plasma 1,5-anhydroglucitol (AG) in diabetic (DM) and non-DM patients in a Chinese population, and to compare it with fructosamine, glycosylated hemoglobin (HbA1c), and fasting glucose (FG) levels.

METHODS:

Case-control study on the significance of AG conducted in a medical center of southern Taiwan, including356 patients (300 non-DM and 56 type 2 DM). Plasma AG, fructosamine, HbA1c and FG were measured on the second day of admission and only those with normal values (except glucose) were enrolled. Glycemic markers of the non-DM patients were examined only once whereas DM patients were sequentially sampled over 3 months.

RESULTS:

Mean plasma AG levels were lower in DM than in non-DM patients (4.02+/-2.96 vs 26.68+/-11.33µg/ml, P<0.001), and lower in non-DM females than males (22.90+/-9.51 vs 29.45+/-11.7µg/ml, P<0.05). AG showed a good correlation with FG. Mean plasma AG were inversely correlated with FG, fructosamine and HbA1c in DM patients and worked as well as other glycemic markers in detecting short-term changes in glycemic control. AG levels of DM patients demonstrated no difference with or without smoking, hypertension, micro- and macro-vascular complications.

CONCLUSIONS:

We recommend clinical application of plasma AG in long-standing DM patients for short-term detection and monitoring glycemic condition.
Assuntos
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Desoxiglucose / Diabetes Mellitus Tipo 2 Tipo de estudo: Observational_studies Limite: Female / Humans / Male Idioma: En Revista: Arq. bras. endocrinol. metab Assunto da revista: ENDOCRINOLOGIA / METABOLISMO Ano de publicação: 2003 Tipo de documento: Article / Project document País de afiliação: China País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Desoxiglucose / Diabetes Mellitus Tipo 2 Tipo de estudo: Observational_studies Limite: Female / Humans / Male Idioma: En Revista: Arq. bras. endocrinol. metab Assunto da revista: ENDOCRINOLOGIA / METABOLISMO Ano de publicação: 2003 Tipo de documento: Article / Project document País de afiliação: China País de publicação: Brasil