Your browser doesn't support javascript.
loading
Determining lead sources in Mexico using the lead isotope ratio
Chaudhary-Webb, Madhu; Paschal, Daniel C; Romieu, Isabelle; Ting, Bill; Elliot, Crawford; Hopkins, Harry; Sanín, Luz Helena; Ghazi, Mahamad A.
Afiliação
  • Chaudhary-Webb, Madhu; Centers for Disease Control and Prevention. Division of Environmental Health Laboratory Sciences. Atlanta. US
  • Paschal, Daniel C; Centers for Disease Control and Prevention. Division of Environmental Health Laboratory Sciences. Atlanta. US
  • Romieu, Isabelle; Pan American Health Organization. México. MX
  • Ting, Bill; Centers for Disease Control and Prevention. Division of Environmental Health Laboratory Sciences. Atlanta. US
  • Elliot, Crawford; Georgia State University. University Plaza. Department of Geology. Atlanta. US
  • Hopkins, Harry; Georgia State University. University Plaza. Department of Chemistry. Atlanta. US
  • Sanín, Luz Helena; Instituto Nacional de Salud Pública. Cuernavaca. MX
  • Ghazi, Mahamad A; Georgia State University. University Plaza. Department of Geology. Atlanta. US
Salud pública Méx ; 45(supl.2): 183-188, 2003. tab, graf
Article em En | LILACS | ID: lil-382737
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVE:

Lead poisoning can, in some cases, be traced to a specific route or source of exposure on the basis of the individual's blood lead isotope ratio. To assess the major source of lead exposure among women residing in Mexico City, we compared blood, ceramic, and gasoline lead isotope ratios. MATERIAL AND

METHODS:

The study population, randomly selected from participants of a large trial, (1/1996-12/1996) comprised of 16 women whose lead levels exceeded 10 æg/dl and who reported using lead-glazed ceramics. Lead isotope ratios were performed on a Perkin Elmer 5000 Inductively Coupled Plasma Mass Spectrometer (ICP-MS) interfaced with a Perkin Elmer HGA-600MS Electrothermal Vaporization System (ETV).

RESULTS:

The isotope ratios (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb) of both the blood specimens and their corresponding ceramic specimens were highly correlated, with r=0.9979, r²=0.9958, r=0.9957, r²=0.9915 and r=0.9945, r²=0.9890 values for the three isotope ratios, respectively, suggesting that the lead exposure most likely resulted from the use of these ceramic. Measurements of lead isotope ratios from leaded gasoline in use at the time of blood sampling, differed from those in blood and ceramics.

CONCLUSIONS:

Determining lead isotope ratios can be an efficient tool to identify a major source of lead exposure and to support the implementation of public health prevention and control measures.
Assuntos
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Radioisótopos de Chumbo / Exposição Ambiental / Intoxicação por Chumbo Tipo de estudo: Clinical_trials Limite: Female / Humans País/Região como assunto: Mexico Idioma: En Revista: Salud pública Méx Assunto da revista: SAUDE PUBLICA Ano de publicação: 2003 Tipo de documento: Article País de afiliação: México / Estados Unidos País de publicação: México
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Radioisótopos de Chumbo / Exposição Ambiental / Intoxicação por Chumbo Tipo de estudo: Clinical_trials Limite: Female / Humans País/Região como assunto: Mexico Idioma: En Revista: Salud pública Méx Assunto da revista: SAUDE PUBLICA Ano de publicação: 2003 Tipo de documento: Article País de afiliação: México / Estados Unidos País de publicação: México