Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año / Experience in the use of a new endocardial stimulation electrode
Frangini S., Patricia; Vergara S., Ismael; González A., Rolando; Baeza L., Mariana; Cambón R., Ana María.
Afiliação
  • Frangini S., Patricia; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • Vergara S., Ismael; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • González A., Rolando; Pontificia Universidad Católica de Chile. Facultad de Medicina. Departamento de Enfermedades Cardiovasculares. Laboratorio de Electrofisiología Cardíaca. Santiago. CL
  • Baeza L., Mariana; s.af
  • Cambón R., Ana María; s.af
Rev. méd. Chile ; 134(6): 749-753, jun. 2006. ilus, tab, graf
Article em Es | LILACS | ID: lil-434623
Biblioteca responsável: BR1.1
ABSTRACT

Background:

Since February 2002, Flextend® electrode catheters are used at the Cardiovascular Unit of the Catholic University Clinical Hospital. These transvenous catheters have an IS-1 connector, silicone coating, active fixation and retractile helix with dexamethasone acetate.

Aim:

To report early and one year results using Flextend® catheters. Material and

methods:

Retrospective analysis of all patients that received an implant of a Flextend® catheter in the Unit.

Results:

Forty one Flextend® catheters were implanted in 24 patients, without acute displacement or clinical pericarditis. In 18 electrode catheters located in the right atrium the mean values for p wave, stimulation threshold and impedance at the moment of placement, were 2.9±1.4 mV, 0.8±0.4 V and 522±86 Ohms, respectively. The figures 24 hours after placement were 3.6±2.1 mV, 0.8±0.3 V and 612±69 Ohms, respectively. In 23 electrode catheters in the right ventricle, mean values at the moment of placement for R wave, stimulation threshold and impedance were 11.3±3.6 mV, 0.8±0.2 V and 756±108 Ohms, respectively. The figures 24 hours after placement were 3.6±2.1 mV, 0.8±0.3 V and 612±69 Ohms, respectively. In one patient, the stimulation threshold increased two months after placement and required a new intervention.

Conclusions:

Flextend® catheters ca be placed successfully with a low rate of complications and stable function parameters on follow up.
Assuntos
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Marca-Passo Artificial / Avaliação da Tecnologia Biomédica / Estimulação Elétrica / Eletrodos Implantados Tipo de estudo: Evaluation_studies / Health_technology_assessment / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male Idioma: Es Revista: Rev. méd. Chile Assunto da revista: MEDICINA Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Chile País de publicação: Chile
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Marca-Passo Artificial / Avaliação da Tecnologia Biomédica / Estimulação Elétrica / Eletrodos Implantados Tipo de estudo: Evaluation_studies / Health_technology_assessment / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male Idioma: Es Revista: Rev. méd. Chile Assunto da revista: MEDICINA Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Chile País de publicação: Chile