Your browser doesn't support javascript.
loading
Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
Ribeiro, Tarsila C. R; Kondo, Mario; Amaral, Ana Cristina C; Parise, Edson Roberto; Bragagnolo Júnior, Maurício A; Souza, Aécio Flávio Meirelles de.
Afiliação
  • Ribeiro, Tarsila C. R; Federal University of São Paulo. São Paulo Medical School. São Paulo. BR
  • Kondo, Mario; Federal University of São Paulo. São Paulo Medical School. São Paulo. BR
  • Amaral, Ana Cristina C; Federal University of São Paulo. São Paulo Medical School. São Paulo. BR
  • Parise, Edson Roberto; Federal University of São Paulo. São Paulo Medical School. São Paulo. BR
  • Bragagnolo Júnior, Maurício A; Federal University of São Paulo. São Paulo Medical School. São Paulo. BR
  • Souza, Aécio Flávio Meirelles de; Federal University of Juiz de Fora. HU. Juiz de Fora. BR
Braz. j. infect. dis ; 11(1): 70-74, Feb. 2007. tab, graf
Artigo em Inglês | LILACS | ID: lil-454685
Biblioteca responsável: BR1.1
ABSTRACT
In order to evaluate the accuracy of a urine reagent dipstick (Multistix 10SG®) to determine ascitic fluid leukocyte count, we prospectively studied 106 cirrhotic patients from April 2003 to December 2004, in two different centers (Federal University of São Paulo - UNIFESP-EPM and Federal University of Juiz de Fora - HU-UFJF) for the rapid bedside diagnosis of spontaneous bacterial peritonitis. The mean age 54 ± 12 years, there was a predominance of males (eighty-two patients, 77 percent), and alcohol was the most frequent etiology (43 percent). Forty-four percent of patients were classified as Child B and fifty-one as Child C (51 percent). Abdominal paracentesis was performed both in outpatient and inpatient settings and the Multistix 10SG® was tested. Eleven cases of spontaneous bacterial peritonitis were identified by means of polymorphonuclear count. If we considered the positive Multistix 10SG® result of 3 or more, the sensitivity, specificity, positive and negative predictive value were respectively 71 percent, 99 percent, 91 percent and 98 percent. With a positive reagent strip result taken as grade 2 (traces) or more, sensitivity was 86 percent and specificity was 96 percent with positive and negative predictive values of 60 percent and 99 percent, respectively. Diagnostic accuracy was 95 percent. We concluded that the use of a urine reagent dipstick (Multistix 10SG®) could be considered a quick, easy and cheap method for ascitic fluid cellularity determination in SBP diagnosis.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Peritonite / Fitas Reagentes / Líquido Ascítico / Infecções por Bactérias Gram-Positivas / Infecções por Bactérias Gram-Negativas Tipo de estudo: Estudo diagnóstico / Estudo de avaliação / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. infect. dis Assunto da revista: Doenças Transmissíveis Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Juiz de Fora/BR / Federal University of São Paulo/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Peritonite / Fitas Reagentes / Líquido Ascítico / Infecções por Bactérias Gram-Positivas / Infecções por Bactérias Gram-Negativas Tipo de estudo: Estudo diagnóstico / Estudo de avaliação / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. infect. dis Assunto da revista: Doenças Transmissíveis Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Juiz de Fora/BR / Federal University of São Paulo/BR
...