Your browser doesn't support javascript.
loading
Distribuição da umidade num perfil de solo irrigado por gotejamento superficial e subsuperficial / Humidity distribution in a soil profile irrigated by surface and buried drip systems
Souza, Elves de Almeida; Coelho, Eugênio Ferreira; Paz, Vital Pedro da Silva.
Afiliação
  • Souza, Elves de Almeida; Prefeitura Municipal de Cruz das Almas. Secretaria de Fazenda. Cruz das Almas. BR
  • Coelho, Eugênio Ferreira; EMBRAPA Mandioca e Fruticultura Tropical. Laboratório de Irrigação e Fertirrigação. Cruz das Almas. BR
  • Paz, Vital Pedro da Silva; Universidade Federal do Reconcavo da Bahia. Nucleo de Engenharia de Agua e Solo. Cruz das Almas. BR
Ciênc. agrotec., (Impr.) ; 31(4): 1161-1166, jul.-ago. 2007. graf
Artigo em Português | LILACS | ID: lil-461581
Biblioteca responsável: BR1.1
RESUMO
Conduziu-se o presente trabalho com o objetivo de avaliar a distribuição de água no perfil de um Latossolo cultivado com mamoeiro do grupo Formosa, irrigado por dois gotejadores por planta instalados a 0,30 m da mesma. Usou-se gotejamento superficial com emissores de vazão de 3,75 L.h-1 e subsuperficial com emissores de vazão foi 2 L.h-1 a 0,25 m de profundidade. Os valores de umidades foram obtidos por meio de sondas de TDR instaladas e distribuídas em perfis de solo. As leituras foram realizadas em intervalos de dez minutos, durante dois ciclos de irrigação, utilizando um sistema de aquisição de dados composto por uma TDR, um datalogger e quatro multiplexadores. Os dados foram analisados a partir de isolinhas de distribuição de umidade e os resultados mostraram que o sistema de gotejamento subsuperficial apresentou uma menor variação da umidade concentrada na direção do sistema radicular do mamoeiro e o armazenamento de água no sistema subsuperficial foi 17 por cento superior ao superficial.
ABSTRACT
This work aimed at evaluating water distribution in a Latossol profile cultivated with papaya of Formosa group, irrigated by two drippers per plant installed at 0.30 m from the plant. Surface drip irrigation with emitters of 3.75 Lh-1flow rate and subsurface drip with emitters of 2 Lh-1 at 0.25 m depth were used. The humidity values were obtained by means of TDR probes installed and distributed in soil profiles. The readings were performed in a ten-minute interval during two irrigation cycles, using a data acquisition system composed by a TDR, one datalloger and four multiplexers. The data were analyzed from isolines of humidity distribution and results showed that the subsurface drip system had a smaller variation of humidity concentrated in the direction of papaya root system. The water storage for the subsurface system was 17 percent larger than the one for surface system.

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Português Revista: Ciênc. agrotec., (Impr.) Assunto da revista: Biologia / Biotecnologia / Ciências da Nutrição / VETERINARIA Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: EMBRAPA Mandioca e Fruticultura Tropical/BR / Prefeitura Municipal de Cruz das Almas/BR / Universidade Federal do Reconcavo da Bahia/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Português Revista: Ciênc. agrotec., (Impr.) Assunto da revista: Biologia / Biotecnologia / Ciências da Nutrição / VETERINARIA Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: EMBRAPA Mandioca e Fruticultura Tropical/BR / Prefeitura Municipal de Cruz das Almas/BR / Universidade Federal do Reconcavo da Bahia/BR
...