Your browser doesn't support javascript.
loading
Avaliação das unidades de tratamento do lodo em uma ete de lodos ativados convencional submetida a distintas estratégias operacionais / Evaluation of the sludge treatment units in an activated sludge treatment plant subjected to different operational strategies
Silva, Alessandra Valadares Álvares da; Von Sperling, Marcos; Oliveira Filho, José Maria de.
Afiliação
  • Silva, Alessandra Valadares Álvares da; FAMIH. Belo Horizonte. BR
  • Von Sperling, Marcos; Universidade de Londres. Imperial College. Londres. GB
  • Oliveira Filho, José Maria de; UFMG. Belo Horizonte. BR
Eng. sanit. ambient ; 12(2): 127-133, abr.-jun. 2007. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-461603
Biblioteca responsável: BR559.1
RESUMO
A finalidade deste trabalho é apresentar uma avaliação da etapa de tratamento de lodos da Estação de Tratamento de Esgotos do Arrudas (Belo Horizonte), em especial os teores de sólidos ao longo do sistema, as principais variáveis de projeto e operação. O processo de tratamento é o de lodos ativados convencional com adensamento por gravidade, digestão anaeróbia e desidratação mecânica. Desde sua entrada em operação até o momento, a estação passou por três fases operacionais quanto ao adensamento dos lodos. A maior concentração média do lodo primário (4,8 por cento) foi atingida no adensador por gravidade quando esse recebia apenas lodo primário. O lodo misto alcançou uma concentração média de 2,7 por cento enquanto o valor esperado de projeto era 5,0 por cento. O lodo secundário excedente, concentrado no adensador por gravidade não ultrapassou 1,8 por cento. A maior concentração média da torta do lodo desidratado (28,3 por cento) foi obtida quando o lodo digerido era proveniente do tratamento primário.
ABSTRACT
This paper aims to evaluate the sludge treatment stage at the Arrudas Wastewater Treatment Plant (Belo Horizonte, Brazil), especially the solids contents throughout the sludge treatment line, as well as the main design and operating variables. The conventional activated sludge plant has a typical solids-line flowsheet gravity thickening, anaerobic digestion and mechanical dewatering. Three main operational phases have been identified, whose implications in the plant behaviour are analysed in the paper. The highest concentration of primary sludge (mean value of 4.8 percent) was reached in the gravitational thickening when it was fed with primary sludge only. The mixed sludge concentrated in the gravitational thickening reached only a mean concentration of 2.7 percent, whereas the expected result was 5.0 percent. The excess secondary sludge concentrated in the gravitational thickener did not reach 1.8 percent. The largest concentration of the dewatered sludge cake (means value of 28.3 percent) was obtained when the digested sludge came from the primary treatment.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Desidratação de Lodos / Digestão Anaeróbia / Adensamento por Gravidade / Tratamento de Lodos / Águas Residuárias Tipo de estudo: Estudo prognóstico Idioma: Português Revista: Eng. sanit. ambient Assunto da revista: Saúde Ambiental / Saúde Pública Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil / Reino Unido Instituição/País de afiliação: FAMIH/BR / UFMG/BR / Universidade de Londres/GB
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Desidratação de Lodos / Digestão Anaeróbia / Adensamento por Gravidade / Tratamento de Lodos / Águas Residuárias Tipo de estudo: Estudo prognóstico Idioma: Português Revista: Eng. sanit. ambient Assunto da revista: Saúde Ambiental / Saúde Pública Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil / Reino Unido Instituição/País de afiliação: FAMIH/BR / UFMG/BR / Universidade de Londres/GB
...