Eletrococleografia extratimpânica na neuropatia/dessincronia auditiva: [revisão] / Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony: [review]
Rev. bras. otorrinolaringol
; 74(1): 132-136, jan.-fev. 2008. ilus
Artigo
em Inglês, Português
| LILACS
| ID: lil-479840
Biblioteca responsável:
BR1.1
RESUMO
O potencial evocado auditivo de tronco encefálico (PEATE) vem sendo amplamente utilizado como método para avaliação da função coclear em indivíduos com diagnóstico de neuropatia/dessincronia auditiva (NA/DA). Na ausência das emissões otoacústicas, muitos casos de NA/DA foram diagnosticados pela presença do microfonismo coclear (MC) identificado no PEATE. OBJETIVO:
Demonstrar a aplicabilidade clínica da eletrococleografia extratimpânica (Ecog-ET) no diagnóstico diferencial da NA/DA quando comparada ao PEATE. MATERIAL EMÉTODO:
Uma criança com 4 anos de idade, com diagnóstico de NA/DA atendida no Centro de Pesquisas Audiológicas realizou a Ecog-ET com tone burst de 2000Hz nas polaridades de rarefação e condensação.RESULTADOS:
Ilustrou-se o registro da Ecog-ET. Com a utilização de protocolo apropriado, o MC pode ser evidenciado e confirmado na Ecog, com qualidade de registro superior ao obtido no PEATE.CONCLUSÃO:
A Ecog-ET permitiu uma análise mais detalhada do MC quando comparada ao PEATE tendo, portanto aplicabilidade clínica na investigação da função coclear na NA/DA.ABSTRACT
The brainstem auditory evoked potential (BAEP) is being extensively used as a method for the evaluation of cochlear function in individuals with diagnosis of auditory neuropathy/auditory dyssynchrony (AN/AD). In the absence of otoacoustic emissions, many cases of AN/AD have been diagnosed by the presence of CM identified in the BAEP. AIM:
to demonstrate the clinical applicability of extratympanic electrocochleography (ET-Ecochg) in the differential diagnosis of AN/AD compared to the BAEP.METHOD:
a 4-year-old child with a diagnosis of AN/AD seen at the Audiological Research Center was submitted to ET-Ecochg with a 2000 Hz tone burst in rarefaction and condensation polarities.RESULTS:
the ET-Ecochg exam was illustrated. Using an appropriate protocol, it was possible to demonstrate CM and to confirm it in the Ecochg, with a recording quality superior to that obtained in the BAEP.CONCLUSION:
ET-Ecochg permitted a more detailed analysis of CM compared to the BAEP, thus showing clinical applicability for the investigation of cochlear function in AN/AD.
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
LILACS
Assunto principal:
Transtornos da Percepção Auditiva
/
Doenças do Nervo Vestibulococlear
/
Potenciais Evocados Auditivos do Tronco Encefálico
/
Potenciais Microfônicos da Cóclea
/
Eletrofisiologia
/
Perda Auditiva
Tipo de estudo:
Estudo diagnóstico
/
Guia de prática clínica
/
Estudo prognóstico
Limite:
Criança, pré-escolar
/
Feminino
/
Humanos
Idioma:
Inglês
/
Português
Revista:
Rev. bras. otorrinolaringol
Assunto da revista:
Otorrinolaringologia
Ano de publicação:
2008
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
USP/BR