Your browser doesn't support javascript.
loading
Fluido oral y orina como muestras alternativas en el diagnóstico confirmatorio de la infección por VIH-1 / Oral fluid and urine as alternative samples in confirmatory testing of HIV-1 infection
Cruz Sui, Otto; Pérez Guevara, María Teresa; Lubián Caballero, Ana Luisa; Montano Tamayo, Lucy; Silva Cabrera, Eladio.
Afiliação
  • Cruz Sui, Otto; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Pérez Guevara, María Teresa; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Lubián Caballero, Ana Luisa; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Montano Tamayo, Lucy; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Silva Cabrera, Eladio; Laboratorio de Investigaciones del SIDA. La Habana. CU
Rev. cuba. med. trop ; 59(2)mayo-ago. 2007. tab, graf
Artigo em Espanhol | LILACS | ID: lil-489534
Biblioteca responsável: CU1.1
RESUMEN
Se evaluó el fluido oral y la orina como muestras opcionales en el diagnóstico confirmatorio del VIH-1 con el sistema DAVIH-BLOT (Laboratorios DAVIH, La Habana, Cuba), para lo cual se comparó con las correspondientes muestras de sueros en un grupo de 125 individuos. En el análisis de los patrones de bandas reveladas, los anticuerpos predominantes en las muestras positivas de fluido oral y orina contra la p34, p68, gp41 y gp120, no tuvieron diferencias con sus correspondientes sueros según la prueba de comparación de proporciones (p< 0,001). La sensibilidad y especificidad relativas del sistema resultaron de 100 por ciento en el análisis del fluido oral; 98,75 y 100 por ciento, respectivamente, en las muestras de orina. Estos resultados apoyan el empleo opcional del fluido oral y la orina que, con ligeras modificaciones introducidas en el sistema diagnóstico, pueden aplicarse para la confirmación de anticuerpos contra el VIH-1.
ABSTRACT
The objective of this report was to evaluate oral fluid and urine as optional samples for HIV-1 confirmatory test using DAVIH-BLOT system (Laboratorios DAVIH, La Habana, Cuba), for which they were compared with their corresponding serum samples in a group of 125 individuals. In band pattern analysis, predominant antibodies in positives oral fluid and urine samples against p34, p68, gp41, gp120, were no different from their corresponding sera according to the proportion comparison test (p<0,001). Relative sensitivity and specificity of this system were 100 pernent in oral fluid and 98, 75 pernent and 100 pernent in urine samples respectively. These results support optional use of oral fluid and urine that, with slight modifications in the diagnostic system, can be applied for HIV-1 antibody confirmation testing.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Saliva / Urina / HIV-1 / Diagnóstico Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Espanhol Revista: Rev. cuba. med. trop Assunto da revista: Medicina Tropical Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Laboratorio de Investigaciones del SIDA/CU
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Saliva / Urina / HIV-1 / Diagnóstico Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Espanhol Revista: Rev. cuba. med. trop Assunto da revista: Medicina Tropical Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Laboratorio de Investigaciones del SIDA/CU
...