Your browser doesn't support javascript.
loading
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin
Schwartzer, Eduardo; Collares, Fabrício Mezzomo; Ogliari, Fabrício Aulo; Leitune, Vicente Castelo Branco; Samuel, Susana Maria Werner.
Afiliação
  • Schwartzer, Eduardo; Federal University of Rio Grande do Sul (UFRGS). Faculty of Dentistry. Department of Conservative Dentistry. Porto Alegre. BR
  • Collares, Fabrício Mezzomo; Federal University of Rio Grande do Sul (UFRGS). Faculty of Dentistry. Department of Conservative Dentistry. Porto Alegre. BR
  • Ogliari, Fabrício Aulo; Federal University of Pelotas (UFPel). Faculty of Dentistry. Department of Conservative Dentistry. Pelotas. BR
  • Leitune, Vicente Castelo Branco; Federal University of Rio Grande do Sul (UFRGS). Faculty of Dentistry. Department of Conservative Dentistry. Porto Alegre. BR
  • Samuel, Susana Maria Werner; Federal University of Rio Grande do Sul (UFRGS). Faculty of Dentistry. Department of Conservative Dentistry. Porto Alegre. BR
Braz. j. oral sci ; 6(23): 1423-1427, Oct.-Dec. 2007. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-518086
Biblioteca responsável: BR28.1
ABSTRACT
The objective of this study was to evaluate the influence of temporary zinc oxide-eugenol cements (ZOEs) on the microtensile bond strength (ìTBS) of an all-in-one adhesive system to dentin. Buccal dentin surface of fifteen bovine incisors were exposed and polished with 600-grit SiC paper. Next, three groups were formed Group 1 (G1), in which the dentin surface was covered with ZOE (TempCem); Group 2 (G2), in which the dentin surface was covered with temporary cement composed of zinc oxide and an aliphatic acid replacing eugenol (TempCem NE); Group 3 (G3) - no temporary cement was used. Each group was individually stored in distilled water at 37º C for 7 days, whereupon temporary cements were mechanically removed. All groups underwent the adhesive protocol with a simplified self-etching adhesive (One-UP Bond F). Four sticks per tooth were obtained, resulting in 20 sticks per group with a cross-sectional area of 0.5 mm2. The ìTBS test was performed with a crosshead speed of 1mm/min. The failure pattern was analyzed by SEM. The data were submitted to one-way ANOVA, at p<0.05. The mean values were 44.67 MPa for G3, followed by 41.35 MPa for G2 and 39.33 MPa for G1. There was no significant statistical difference between groups. The failure pattern was almost mixed with the adhesive layer and dentin. The eugenol presented in TempCem did not influence the ìTBS test when a simplified selfetching adhesive system was used.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Cimento de Óxido de Zinco e Eugenol / Eugenol / Adesivos Dentinários / Dentina Limite: Animais Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Pelotas (UFPel)/BR / Federal University of Rio Grande do Sul (UFRGS)/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Cimento de Óxido de Zinco e Eugenol / Eugenol / Adesivos Dentinários / Dentina Limite: Animais Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Pelotas (UFPel)/BR / Federal University of Rio Grande do Sul (UFRGS)/BR
...