Your browser doesn't support javascript.
loading
Análise da fluoretação da água de abastecimento público da zona urbana do município de Campo Grande (MS) / Water fluoridation analysis of Campo Grande (MS) urban zone public supply
Bellé, Bruno Luiz Lessa; Lacerda, Valéria Rodrigues de; Carli, Alessandro Diogo De; Azfalon, Edílson José; Pereira, Paulo Zárate.
Afiliação
  • Bellé, Bruno Luiz Lessa; UFMS. Faculdade de Odontologia Prof. Albino Coimbra Filho. BR
  • Lacerda, Valéria Rodrigues de; UFMS. Faculdade de Odontologia Prof. Albino Coimbra Filho. BR
  • Carli, Alessandro Diogo De; UFMS. Faculdade de Odontologia Prof. Albino Coimbra Filho. BR
  • Azfalon, Edílson José; UFMS. Faculdade de Odontologia Prof. Albino Coimbra Filho. BR
  • Pereira, Paulo Zárate; UFMS. Faculdade de Odontologia Prof. Albino Coimbra Filho. BR
Ciênc. Saúde Colet. (Impr.) ; Ciênc. Saúde Colet. (Impr.);14(4): 1261-1266, julho-ago. 2009. tab
Article em Pt | LILACS | ID: lil-523957
Biblioteca responsável: BR1.1
RESUMO
O presente estudo teve por objetivo analisar a concentração de fluoreto na água que flui das torneiras da zona urbana do município de Campo Grande (MS). Para tanto, foram coletadas amostras de água de 21 escolas situadas nos sete subdistritos da cidade, em três oportunidades diferentes para análise do teor de fluoreto, determinada pelo método do eletrodo específico (medidor de fluoreto combinado Orion 9609 BN, acoplado a um potenciômetro digital EA-940 da Orion). Os resultados mostraram que 63,5 por cento das amostras coletadas apresentaram níveis aceitáveis (entre 0,6 a 0,8 ppm) de fluoreto e 36,5 por cento, níveis inaceitáveis. Em relação à condição dos locais de coleta, 76,2 por cento foram consideradas adequadas e 23,8 por cento, inadequadas.
ABSTRACT
The objective of this study was to analyze the fluoride concentration on the water that flows of the tap in the urban area of the city of Campo Grande (MS). For the fluoride concentration analysis, it was collected water samples of 21 schools placed in the 7 sub districts of the city, in 3 different opportunities, was made by the specific electrode method (using an Orion 9609 BN combined fluoride measuring electrode, coupled with an Orion EA-940 digital potentiometer). The results showed that 63.5 percent of the water samples presented acceptable fluoride levels (between 0.60 and 0.80 ppm) and 36.5 percent, unacceptable levels. In relation to the condition of the collect places, 76.2 percent were considered appropriate and 23.8 percent were inappropriate.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Água / Fluoretação / Fluoretos País/Região como assunto: America do sul / Brasil Idioma: Pt Revista: Ciênc. Saúde Colet. (Impr.) Assunto da revista: SAUDE PUBLICA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Água / Fluoretação / Fluoretos País/Região como assunto: America do sul / Brasil Idioma: Pt Revista: Ciênc. Saúde Colet. (Impr.) Assunto da revista: SAUDE PUBLICA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil