Your browser doesn't support javascript.
loading
O stent descoberto não promove reações em artérias renais e parênquima renal em suínos / Uncovered stent does not provoke reactions in renal arteries and renal parenchyma in swines
Bombonato, Rubio; Palma, José Honório; Marcondes, José Augusto; Moraes, Aury Nunes de; Rocha, João Luiz da; Martins, Marcio Rodrigo; Tchaick, Rodrigo Mezzalira; Buffolo, Enio.
Afiliação
  • Bombonato, Rubio; INCOR. Hospital Maternidade Marieta Konder Bonhausem. BR
  • Palma, José Honório; Unifesp. BR
  • Marcondes, José Augusto; UNIFESP - Escola Paulista de Medicina São Paulo. BR
  • Moraes, Aury Nunes de; Universidade do Estado de Santa Catarina. Hospital Veterinário. BR
  • Rocha, João Luiz da; Laboratório Rocha. Criciúma. BR
  • Martins, Marcio Rodrigo; Hospital São José. Criciúma. BR
  • Tchaick, Rodrigo Mezzalira; Santa Casa. Curitiba. BR
  • Buffolo, Enio; Unifesp. BR
Rev. bras. cir. cardiovasc ; 24(2): 126-132, abr.-jun. 2009. ilus
Artigo em Inglês, Português | LILACS | ID: lil-525543
Biblioteca responsável: BR1.1
RESUMO
OBJETIVO: Avaliar as alterações histológicas da aorta, artéria renal e parênquima renal, em suínos, induzidos pelo stent metálico descoberto implantado em localização transrenal na aorta abdominal. MÉTODOS: Foram utilizados 10 suínos com peso médio de 86,6 quilos e idade média de 6 meses, submetidos a implante de stent metálico posicionado na aorta, no nível das artérias renais, após 100 dias do implante. Os stents foram liberados por auto-expansão com laparotomia. Foram realizadas análises anatômicas e histológicas da aorta abdominal, artérias renais e parênquima renal. Os cortes histológicos foram realizados nos seguintes locais: 1) transição entre a aorta normal e aorta contendo stent; 2) porção contendo os óstios das artérias renais, 3) parênquima renal. As lâminas foram coradas pela técnica da hematoxilina e eosina e analisadas conforme protocolo de análise histológica aplicada na prática clínica dos laboratórios de patologia. RESULTADOS: Os achados macroscópicos revelaram espessamento da parede aórtica; artérias renais pérvias; estrutura anatômica renal normal. Análises microscópicas, próximas aos stents, evidenciaram espessamento da parede vascular, artérias renais sem alterações e parênquima renal preservado. CONCLUSÃO: O stent de aço inoxidável descoberto produziu importante reação inflamatória com espessamento da parede da aorta. No entanto, as artérias renais permaneceram pérvias e o parênquima renal sem alterações isquêmicas ou embólicas.
ABSTRACT
OBJECTIVE: To assess the histological changes of the aorta, the renal arteries and the renal parenchyma in swine, induced by a metalic uncovered stent implanted in transrenal position in the abdominal aorta. METHODS: Ten pigs with a mean weight of 86.6 kg and mean age of 6 months underwent implantation of metal stent graft placed in the aorta at the level of the renal arteries after 100 days of implantation. The self-expanding stents were released by laparotomy. Anatomic and histological analyses of the abdominal aorta, the renal arteries and the renal parenchyma were performed. Histological slices were performed in the following sites: 1) transitional zone between the aorta with and without stent graft; 2) portion of the renal arteries ostia; 3) renal parenchyma. The slices were stained through the hematoxylin and eosin stain technique and analyzed according the protocol of histological analyses applied in the clinical practice of pathology labs. RESULTS: The macroscopic findings showed thickening of the aortic wall; patent renal arteries; and normal anatomic renal structures. Microscopic analyses, close to the stents, showed thickening of the vascular wall, renal arteries without changes, and preserved renal parenchyma. CONCLUSION: The uncovered stainless steel stent caused a significant inflammatory reaction with thickening of the aortic wall. However, the renal arteries remained patent and the renal parenchyma did not present embolic or ischemic changes.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Aorta Abdominal / Artéria Renal / Prótese Vascular / Stents / Reação a Corpo Estranho / Rim Tipo de estudo: Guia de prática clínica / Estudo prognóstico Limite: Animais Idioma: Inglês / Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / CIRURGIA GERAL Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital São José/BR / INCOR/BR / Laboratório Rocha/BR / Santa Casa/BR / UNIFESP - Escola Paulista de Medicina São Paulo/BR / Unifesp/BR / Universidade do Estado de Santa Catarina/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Aorta Abdominal / Artéria Renal / Prótese Vascular / Stents / Reação a Corpo Estranho / Rim Tipo de estudo: Guia de prática clínica / Estudo prognóstico Limite: Animais Idioma: Inglês / Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / CIRURGIA GERAL Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital São José/BR / INCOR/BR / Laboratório Rocha/BR / Santa Casa/BR / UNIFESP - Escola Paulista de Medicina São Paulo/BR / Unifesp/BR / Universidade do Estado de Santa Catarina/BR
...