Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínico / Bridge to lung transplantation with a novel pumpless lung assist device: Report of one case
Fernández, Patricio; Muñoz, Pablo; Fischer, Danilo; Méndez, Felipe; Florenzano, Matías; Valdés, Sergio; Parada, María Teresa; Fica, Mauricio; Rodríguez, Patricio; Díaz, Rodrigo; Rufs, Jorge.
Afiliação
  • Fernández, Patricio; Universidad de Chile. Facultad de Medicina. Santiago. CL
  • Muñoz, Pablo; Universidad de Chile. Centro de Pacientes Críticos. Santiago. CL
  • Fischer, Danilo; Universidad de Chile. Centro de Pacientes Críticos. Santiago. CL
  • Méndez, Felipe; Universidad de Chile. Centro de Pacientes Críticos. Santiago. CL
  • Florenzano, Matías; Universidad de Chile. Centro de Pacientes Críticos. Santiago. CL
  • Valdés, Sergio; Universidad de Chile. Centro de Pacientes Críticos. Santiago. CL
  • Parada, María Teresa; Universidad de Chile. Departamento de Medicina Interna. Santiago. CL
  • Fica, Mauricio; Universidad de Chile. Unidad de Cirugía Torácica. Santiago. CL
  • Rodríguez, Patricio; Universidad de Chile. Unidad de Cirugía Torácica. Santiago. CL
  • Díaz, Rodrigo; Clínica Las Condes. Departamento de Anestesiología. Santiago. CL
  • Rufs, Jorge; Clínica Las Condes. Departamento de Anestesiología. Santiago. CL
Rev. méd. Chile ; 137(10): 1363-1366, oct. 2009. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-534045
Biblioteca responsável: BR1.1
ABSTRACT
Devices such as Novalung® can be used as a bridge to lung transplantation while waiting for a suitable donor. We report a 50 year-old male with a terminal pulmonary fibrosis and candidate for lung transplantation. He was admitted to the hospital due to a severe deterioration of his respiratory condition, with the presence of severe respiratory acidosis despite conventional invasive respiratory support. Respiratory support with Novalung® was started, resulting in a progressive reduction ofpCOz that became normal ten hours after the installation of the device. Five days later a successful lung transplantation wasperformed.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Acidose Respiratória / Cuidados Pré-Operatórios / Oxigenação por Membrana Extracorpórea / Transplante de Pulmão Limite: Humanos / Masculino Idioma: Espanhol Revista: Rev. méd. Chile Assunto da revista: Medicina Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Chile Instituição/País de afiliação: Clínica Las Condes/CL / Universidad de Chile/CL
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Acidose Respiratória / Cuidados Pré-Operatórios / Oxigenação por Membrana Extracorpórea / Transplante de Pulmão Limite: Humanos / Masculino Idioma: Espanhol Revista: Rev. méd. Chile Assunto da revista: Medicina Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Chile Instituição/País de afiliação: Clínica Las Condes/CL / Universidad de Chile/CL
...