Efeitos da anemia materna na cardiotocografia computadorizada e perfil biofísico fetal / Effects of maternal anemia on computerized cardiotocography and fetal biophysical profile
Nomura, Roseli Mieko Yamamoto; Gordon, Marina Caldana; Fatobene, Giancarlo; Igai, Ana Maria Kondo; Zugaib, Marcelo.
Afiliação
  • Nomura, Roseli Mieko Yamamoto; Universidade de São Paulo. Departamento de Obstetrícia e Ginecologia. Faculdade de Medicina. São Paulo. BR
  • Gordon, Marina Caldana; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Fatobene, Giancarlo; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Igai, Ana Maria Kondo; Universidade de São Paulo. Clínica Obstétrica do Hospital das Clínicas. Faculdade de Medicina. São Paulo. BR
  • Zugaib, Marcelo; Universidade de São Paulo. Departamento de Obstetrícia e Ginecologia. Faculdade de Medicina. São Paulo. BR
Rev. bras. ginecol. obstet ; 31(12): 615-620, dez. 2009. tab
Artigo em Português | LILACS | ID: lil-536741
Biblioteca responsável: BR1.1
RESUMO

OBJETIVOS:

avaliar a influência dos níveis de hemoglobina (Hb) materna nos padrões da frequência cardíaca fetal (FCF) e no perfil biofísico fetal (PBF) em gestações a termo.

MÉTODOS:

gestantes portadoras de anemia (Hb<11,0 g/dL) foram avaliadas prospectivamente, entre a 36ª e a 40ª semana de gestação, no período compreendido entre janeiro de 2008 e março de 2009. O Grupo Controle foi constituído por gestantes de termo, saudáveis, com valores normais de hemoglobina (Hb>11,0 g/dL). Foram excluídos casos com anomalias ou restrição do crescimento fetal. A avaliação da FCF foi realizada pela cardiotocografia computadorizada (Sistema8002-Sonicaid) e análise do traçado com 30 minutos de exame. O PBF foi realizado em todas as pacientes. Foram utilizados os testes t de Student, teste do χ2 e teste exato de Fisher. O nível de significância utilizado foi de 0,05.

RESULTADOS:

A média da Hb materna no grupo com anemia (n=18) foi de 9,4 g/dL (DP=1,4 g/dL) e no Grupo Controle 12,4 g/dL (DP=1,3 g/dL). Quanto aos parâmetros da cardiotocografia, não foi constatada diferença significativa nas médias entre os grupos com anemia e controle, respectivamente FCF basal (131,3 bpm versus 133,7 bpm, p=0,5), acelerações da FCF > 10 bpm (7,9 versus. 8,2, p=0,866), acelerações da FCF > 15 bpm (5,2 versus 5,4, p=0,9), episódios de alta variação da FCF (17,1 versus 15,5 min, p=0,5), episódios de baixa variação da FCF (4,4 versus 3,6 min, p=0,6), e variação de curto prazo (10,5 versus 10,9 ms, p=0,5). Em ambos os grupos, todas as pacientes apresentaram PBF normal.

CONCLUSÕES:

este estudo sugere que a anemia materna leve ou moderada, sem outras comorbidades maternas ou fetais, não se associa a anormalidades nos parâmetros do perfil biofísico fetal e da FCF analisada pela cardiotocografia computadorizada.
ABSTRACT

PURPOSES:

to evaluate the influence of maternal hemoglobin (Hb) levels in the patterns of fetal heart rate (FHR) and in the fetal biophysical profile (FBP) in term gestations.

METHODS:

pregnant women with anemia (Hb<11.0 g/dL) were prospectively evaluated between the 36th and the 40th week of gestation, from January 2008 to March 2009. The Control Group was composed of term and healthy pregnant women, with normal values of hemoglobin (Hb>11,0 g/dL). Cases of anomalies or fetal growing restrictions were excluded. The FHR evaluation was performed by computerized cardiotocography (8002 System-Sonicaid), and by record analysis during 30 minutes of exam. The FBP was done in all the patients. Student's, χ2 and Fisher's exact tests were used, with 0.05 significance level.

RESULTS:

The average of maternal Hb in the group with anemia (n=18) was 9.4 g/dL (DP=1.4 g/dL), and in the control group, 12.4g/dL (DP=1.3 g/dL). There has been no significant mean differences between groups concerning the cardiotocography parameters, respectively basal FHR(131.3 versus 133.7 bpm, p=0.5), FHR accelerations > 10b pm (7.9 versus 8.2, p=0.866), FHR accelerations > 15 bpm (5.2 versus. 5.4, p=0.9), episodes of high variation of the FHR (17.1 versus 15.5 min, p=0,5), episodes of variation of the FHR (4.4 versus 3.6 min, p=06), and short term variation (10.5 versus 10.9 ms, p=0.5). In both groups, all patients presented normal FBP.

CONCLUSIONS:

this study suggests that light or moderate maternal anemia, without other maternal or fetal comorbidity, is not associated with abnormalities in the parameters of fetal biophysical profile and of the FHR analyzed by computerized cardiotocography.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Complicações Hematológicas na Gravidez / Cardiotocografia / Feto / Anemia Limite: Adulto / Feminino / Humanos / Gravidez Idioma: Português Revista: Rev. bras. ginecol. obstet Assunto da revista: Ginecologia / Obstetrícia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Complicações Hematológicas na Gravidez / Cardiotocografia / Feto / Anemia Limite: Adulto / Feminino / Humanos / Gravidez Idioma: Português Revista: Rev. bras. ginecol. obstet Assunto da revista: Ginecologia / Obstetrícia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR
...