Your browser doesn't support javascript.
loading
Avaliação do padrão respiratório com base no índice diafragmático obtido pela biofotogrametria computadorizada / Assessment of respiratory pattern through diaphragmatic index using computerized biophotometer
Godoy, Viviana Alessandra Honório de; Lautenschlaeger, Juliana; Deloroso, Frederico Tadeu; Guedes, Cristina Veloso; Alves, Marcelo Corrêa.
Afiliação
  • Godoy, Viviana Alessandra Honório de; Centro Universitário Hermínio Ometto. Araras. BR
  • Lautenschlaeger, Juliana; Centro Universitário Hermínio Ometto. Araras. BR
  • Deloroso, Frederico Tadeu; Centro Universitário Hermínio Ometto. Araras. BR
  • Guedes, Cristina Veloso; Centro Universitário Hermínio Ometto. Araras. BR
  • Alves, Marcelo Corrêa; Faculdade de Odontologia de Piracicaba. Piracicaba. BR
Fisioter. Bras ; 10(2): 99-105, mar.-abr. 2009.
Artigo em Português | LILACS | ID: lil-546609
Biblioteca responsável: BR1561.1
RESUMO

Objetivo:

Este estudo teve como objetivo avaliar o padrão respiratório por meio do índice diafragmático obtido pela biofotogrametria computadorizada. Material e

métodos:

Foram selecionados quarenta voluntários sadios, 20 homens e 20 mulheres, faixa etária entre 18 e 25 anos. As medidas que classificou os índices para o padrão respiratório foram obtidas em três momentos repouso, inspiração e expiração máxima, na posição ortostática, em vista anterior e perfis. Os valores obtidos na cirtometria possibilitaram classificar o índice diafragmático (ID) pela fórmula ID = ∆ AB/∆ AB + ∆ CT. Para obtenção dos valores da biofotogrametria computadorizada, foi necessário registrar as imagens dos voluntários com pontos previamente demarcados no tórax e abdome por meio de uma câmera digital que permitiu a quantificação angular com auxílio do software ALCimage2.1.

Resultados:

Com os dados obtidos pela biofotogrametria, foi possível classificar o índice diafragmático (ID) pela fórmula ID = - 1.04255 + 0,01969 x a3 exp per esq – 0,03461 x a1 exp per dir – 0.10782 x a2 exp per dir – Índice Diafragmático segundo GDLV (Godoy, Deloroso, Lautenschlaeger e Veloso).

Conclusão:

Observamos neste estudo uma existente correlação entre os dados do padrão respiratório e os da biofotogrametria, podendo sim avaliar o índice diafragmático através da biofotogrametria aplicando a fórmula ID de GDLV.
ABSTRACT

Objective:

The aim of this study was to assess the respiratory pattern through diaphragmatic index (DI) by computerized biophotometer.

Methods:

Forty health young individuals were studied, 20 male and 20 female, aged group between 18 to 25 years old. The measurements were taken in orthostatic position at three different points at rest, maximal inspiration and maximal expiration on anterior and lateral position. The obtained values through cirtometry enable us to classify the diaphragmatic index using the following formula DI = ∆ AB/∆ AB + ∆ CT. In order to obtain the computerized biophotometer values, the individuals were demarcated in the chest and abdomen and using a digital camera their images were registered and for the quantification of the angle it was used the software ALCimage2.1.

Results:

After collecting biophotometer data, the diaphragmatic index (ID) was classified by formula DI = - 1.04255 + 0.01969 x exp a3 per esq - 0.03461 x a1 exp per say - a2 x exp 0.10782 per dir (Diaphragmatic Index according to GDLV (Godoy, Deloroso, Lautenschlaeger and Veloso).

Conclusion:

It was observed, in this study, that there is a correlation between data of the respiratory pattern and of the biophotometer, and it was possible to evaluate the diaphragmatic index using DI formula of GDLV.
Assuntos
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Respiração / Testes de Função Respiratória / Sistema Respiratório / Testes Respiratórios / Diafragma / Mecânica Respiratória / Trabalho Respiratório Idioma: Português Revista: Fisioter. Bras Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário Hermínio Ometto/BR / Faculdade de Odontologia de Piracicaba/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Respiração / Testes de Função Respiratória / Sistema Respiratório / Testes Respiratórios / Diafragma / Mecânica Respiratória / Trabalho Respiratório Idioma: Português Revista: Fisioter. Bras Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário Hermínio Ometto/BR / Faculdade de Odontologia de Piracicaba/BR
...