Your browser doesn't support javascript.
loading
Relación acomodación convergencia por acomodación (Ac/A) con el método del gradiente en un pequeño grupo poblacional de la Ciudad De Pereira / Relation between accommodation and convergence by accommodation (AC/A) with the gradient method in a small population group of Pereira
León Álvarez, Alejandro; Pulgarín, Cesar Augusto.
Afiliação
  • León Álvarez, Alejandro; Fundación Universitaria del Área Andina Pereira. Pereira. CO
  • Pulgarín, Cesar Augusto; Fundación Universitaria del Área Andina Pereira. Pereira. CO
Cienc. tecnol. salud vis. ocul ; (8): 29-36, ene.-jun. 2007. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-552412
Biblioteca responsável: CO149.2
RESUMEN
El propósito de este estudio fue determinar el valor promedio de la relación AC/A calculada con el método del gradiente en un pequeño grupo poblacional de la ciudad de Pereira y establecer el lente estímulo más pertinente para calcular esta sinergia.

Metodología:

se evaluaron 66 personas con edades entre 16 y 30 años, a los cuales se realizó distancia interpupilar, agudeza visual , heteroforias visión lejana (VL) y visión próxima (VP), forias inducidas y AC/A gradiente Resultadas se obtuvo un AC/A gradiente de 13,12 (SD =1.30); con el lente estímulo de +1.00, 13,41 (SD = 1,59), -1.00 D 12,82 (SD = 1,45), -2.00 D, 13,11 (SD =1,27), y -3.00 D, 13,18 (SD =1,27). La mejor correlación se obtuvo con los lentes de -2.00 y -3.00 D (SD =0.76) y la peor con los lentes de +1.00 y -1.00 D (SD =0.15).

Conclusiones:

La relación AC/A gradiente es menor a la reportada en la literatura y existe una significativa variabilidad al ser medida con diferentes lentes estímulo.
ABSTRACT
The purpose of this study was to determine theaverage value of the relation AC/A estimated with thegradient method in a small population group of Pereiraand to establish the most appropriate stimulus lensto calculate such synergy.

Methods:

66 people wereevaluated between 16 and 30 years old who had thefollowing examination inter pupilary distance, visualacuity, heterophories, near vision, far vision, inducedphories, and AC/A gradient.

Results:

an AC/A gradientof 13,12 (SD =1.30) was obtained; with an stimuluslens of +1.00, 13,41 (SD = 1,59), -1.00 D 12,82 (SD= 1,45), -2.00 D, 13,11 (SD =1,27), y -3.00 D, 13,18(SD =1,27). The best correlation was obtained withlenses -2.00 and -3.00 D (SD =0.76) and the worst withlenses +1.00 and -1.00 D (SD =0.15).

Conclusions:

therelation AC/A gradient was lower than the reported inliterature and there was a significant variability when itwas measured with different stimulus lenses.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Acomodação Ocular / Lentes Idioma: Espanhol Revista: Cienc. tecnol. salud vis. ocul Assunto da revista: Informática Médica / Oftalmologia / Optometria / TECNOLOGIA Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Fundación Universitaria del Área Andina Pereira/CO
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Acomodação Ocular / Lentes Idioma: Espanhol Revista: Cienc. tecnol. salud vis. ocul Assunto da revista: Informática Médica / Oftalmologia / Optometria / TECNOLOGIA Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Fundación Universitaria del Área Andina Pereira/CO
...