OBJETIVO: Avaliar a acuidade visual a distancia, intermediária e perto após o implante de uma lente intraocular (LIO) asférica multifocal difrativa AcrySof® ReSTOR® SN6AD1. MÉTODOS: Estudo prospectivo de 50 pacientes com catarata submetidos à facoemulsificação e implante de LIO AcrySof® ReSTOR®. Foram avaliados acuidade visual sem correção (AVSC), acuidade visual com correção (AVCC) para longe, acuidade visual para perto corrigida para longe (AVPC) e acuidade visual intermediária corrigida para longe (AVIC). Um questionário de satisfação e fenômenos visuais foi administrado ao final do estudo. RESULTADO: Após três meses de cirurgia, a média das acuidades (logMAR) era: AVSC, 0,05 ± 0,07; AVCC, 0,00 ± 0,01; AVPC, 0,00 ± 0,0, e AVIC, 0,15 ± 0,05. A AVCC e AVPC era de 20/25 ou melhor em todos os pacientes, sendo a AVIC J3 ou melhor em 83 por cento dos pacientes. Pacientes relataram excelente desempenho visual nas questões relacionadas a atividades para distância, intermediário, e perto com pouca ou nenhuma dificuldade. Nenhum paciente relatou halos ou 'glare' severos, sendo os mesmos caracterizados entre nenhum a moderado. CONCLUSÃO: A LIO asférica AcrySof® ReSTOR® SN6AD1 mostrou excelentes resultados na visão para longe, perto e intermediário, além de apresentar uma baixa incidência de fenômenos visuais.
ABSTRACT
PURPOSE: To evaluate distance, intermediate, and near vision after aspheric multifocal diffractive AcrySof® ReSTOR® SN6AD1 intraocular lens (IOL) implantation. METHODS: Prospective study of 50 patients with cataract that had phacoemulsification and AcrySof® ReSTOR® IOL implantation. Uncorrected distance vision acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity (DCIVA) were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered at the end of the study. RESULTS: Three months postoperatively, the mean acuities (logMAR) were: UCDV, 0,05 ± 0,07; CDVA, 0,00 ± 0,01; DCNVA, 0,00 ± 0,0, and AVIC, 0,15 ± 0,05. The CDVA and DCNVA were 20/25 or better in all patients, with DCIVA of J3 or better in 83 percent of the patients. Patients reported good performance for distance, intermediate, and near visual tasks with no or minimal difficulty with specific tasks. No patient reported severe visual phenomena; halos and glare were rated as none to moderate. CONCLUSION: The aspheric IOL AcrySof® ReSTOR® SN6AD1 provide good functional vision at far, intermediate, and near distance, and a low incidence of visual disturbances.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Qualidade de Vida / Refração Ocular / Visão Binocular / Acuidade Visual / Inquéritos e Questionários / Satisfação do Paciente / Facoemulsificação / Implante de Lente Intraocular / Lentes Intraoculares Tipo de estudo: Estudo observacional / Fatores de risco Aspecto: Preferência do paciente Limite: Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Oftalmológico de Brasília/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Qualidade de Vida / Refração Ocular / Visão Binocular / Acuidade Visual / Inquéritos e Questionários / Satisfação do Paciente / Facoemulsificação / Implante de Lente Intraocular / Lentes Intraoculares Tipo de estudo: Estudo observacional / Fatores de risco Aspecto: Preferência do paciente Limite: Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Oftalmológico de Brasília/BR
...