Your browser doesn't support javascript.
loading
Confiabilidade da versão brasileira do Wolf Motor Function Test em adultos com hemiparesia / Reliability of the brazilian version of the Wolf Motor Function Test in adults with hemiparesis
Pereira, Natalia D; Michaelsen, Stella M; Menezes, Isabella S; Ovando, Angélica C; Lima, Renata C. M; Teixeira-Salmela, Luci F.
Afiliação
  • Pereira, Natalia D; Universidade do Estado de Santa Catarina. Programa de Pós-graduação em Ciências do Movimento Humano. Florianópolis. BR
  • Michaelsen, Stella M; Universidade do Estado de Santa Catarina. Programa de Pós-graduação em Ciências do Movimento Humano. Florianópolis. BR
  • Menezes, Isabella S; Associação de Assistência à Criança Deficiente. São Paulo. BR
  • Ovando, Angélica C; Universidade do Estado de Santa Catarina. Programa de Pós-graduação em Ciências do Movimento Humano. Florianópolis. BR
  • Lima, Renata C. M; Universidade Federal de Minas Gerais. Programa de Pós-graduação em Ciências da Reabilitação. Belo Horizonte. BR
  • Teixeira-Salmela, Luci F; Universidade Federal de Minas Gerais. Programa de Pós-graduação em Ciências da Reabilitação. Belo Horizonte. BR
Braz. j. phys. ther. (Impr.) ; 15(3): 257-265, maio-jun. 2011. graf, tab
Artigo em Português | LILACS | ID: lil-596263
Biblioteca responsável: BR1.1
RESUMO
CONTEXTUALIZAÇÃO O Wolf Motor Function Test (WMFT) avalia o membro superior (MS) de adultos com hemiparesia combinando medidas de tempo e qualidade de movimento em movimentos isolados e em tarefas funcionais.

OBJETIVOS:

Traduzir e adaptar para a língua portuguesa o formulário, a escala de habilidade funcional (EHF) e o manual de aplicação do WMFT e avaliar a confiabilidade intra e inter-observadores.

MÉTODOS:

Participaram 15 indivíduos com média de idade de 57,9±11,1 anos e 68,5±53,5 meses pós acidente vascular encefálico (AVE). O WMFT foi aplicado por um fisioterapeuta utilizando as informações do manual e cotado por dois outros fisioterapeutas independentes pela observação dos vídeos. Foram acrescentadas informações mais detalhadas na EHF sobre a movimentação compensatória em relação à escala original. A confiabilidade intra e interobservadores do desempenho no tempo e da EHF dos itens individuais e do escore total foi avaliada pelo Coeficiente de Correlação Intraclasse (CCI) e pelo método Bland e Altman. Kappa ponderado (Kp) foi utilizado para avaliar a concordância intra e interobservadores da EHF.

RESULTADOS:

O CCI interobservador do desempenho no tempo foi >0,75 em 13 das 15 tarefas. A EHF apresentou CCI interobservador entre 0,87 e 0,99 em todas as tarefas e Kp entre 0,63 e 0,92. O CCI intraobservador do tempo variou entre 0,99 e 1 e na EHF, entre 0,96 e 1. O Kp intraobservador na EHF nas tarefas variou entre 0,79 e 0,96, sendo 0,93 para o escore total.

CONCLUSÃO:

A versão brasileira do WMFT demonstrou confiabilidade adequada para avaliar o MS parético pós-AVE.
ABSTRACT

BACKGROUND:

The Wolf Motor Function Test (WMFT) evaluates the upper limb (UL) performance of adults with hemiparesis by combining time and quality of movement measures in both isolated movements and functional tasks.

OBJECTIVES:

To translate and adapt the WMFT form, functional ability scale (FAS) and manual to Brazilian Portuguese and evaluate the intra and inter-rater reliabilities.

METHODS:

Fifteen individuals with a mean age of 57.9±11.1 years and a mean time since stroke onset of 68.5±53.5 months participated. The WMFT was administered by one physiotherapist based on information in the manual, and video observations were assessed by two other independent physical therapists. Information regarding compensatory movements was included in the FAS. Intra-class correlation coefficients (ICCs) and Bland-Altman plots were calculated to examine the intra- and inter-rater reliabilities for performance time and FAS, whereas weighted kappa (Kp) was used to examine the agreement strength for FAS.

RESULTS:

The inter-rater ICC values for performance time were above 0.75 in 13 of the 15 tasks. For the FAS, they ranged from 0.87-0.99 for all evaluated tasks, with Kp values ranging from 0.63-0.92. For intra-rater reliability, the ICC ranged from 0.99-1.0 and from 0.96-1.0 for time measurement and FAS, respectively. Kp values ranged from 0.79-0.96 for individual and 0.93 for total scores.

CONCLUSION:

The Brazilian version of the WMFT showed adequate intra- and inter-rater reliabilities for evaluating the paretic UL of individuals with stroke.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Paresia / Extremidade Superior Tipo de estudo: Estudo de etiologia / Guia de prática clínica Limite: Adulto / Idoso / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Braz. j. phys. ther. (Impr.) Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Associação de Assistência à Criança Deficiente/BR / Universidade Federal de Minas Gerais/BR / Universidade do Estado de Santa Catarina/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Paresia / Extremidade Superior Tipo de estudo: Estudo de etiologia / Guia de prática clínica Limite: Adulto / Idoso / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Braz. j. phys. ther. (Impr.) Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Associação de Assistência à Criança Deficiente/BR / Universidade Federal de Minas Gerais/BR / Universidade do Estado de Santa Catarina/BR
...