RESUMO
INTRODUÇÃO: O teste de supressão com 1 mg de dexametasona (TSDx) é amplamente empregado no rastreamento da síndrome de Cushing (SC) dada sua elevada acurácia diagnóstica. A SC é um distúrbio endocrinometabólico resultante do hipercortisolismo crônico com característica de ausência de supressão do cortisol no TSDx. OBJETIVO: Desenvolver um radioimunoensaio (RIE) para a dosagem de dexametasona (Dx) no soro para complementar o TSDx. MÉTODOS: Foram imunizados três coelhos com o conjugado dexametasona-21-hemissuccinato-BSA para escolha do melhor anticorpo e o RIE foi desenvolvido de acordo com as recomendações da RE 899/2003 da Agência Nacional de Vigilância Sanitária (ANVISA). Analisamos 96 voluntários, sendo 67 submetidos ao TSDx e 29 não, e 12 pacientes com SC, estudados na Universidade Federal de São Paulo (UNIFESP) e na Santa Casa de Misericórdia de São Paulo. RESULTADOS: O anticorpo contra Dx selecionado mostrou boa especificidade, coeficiente de variação (CV por cento) intra e interensaio < 20 por cento, exatidão de 93,8 por cento e dose mínima detectada de 19,5 ng/dl. A concentração de Dx no soro foi semelhante nos voluntários e pacientes com SC (ausência/supressão do cortisol): 205 a 703 ng/dl e 174 a 661 ng/dl (intervalo de confiança [IC] 95 por cento), respectivamente; os valores foram indetectáveis naqueles que não se submeteram ao teste. DISCUSSÃO: O anticorpo empregado apresenta boa afinidade e especificidade para quantificar a Dx no soro. O RIE mostrou reprodutibilidade e eficiência na determinação dos níveis séricos de Dx durante o TSDx. CONCLUSÃO: O presente RIE para a dosagem de Dx no soro é acurado e confiável, permitindo estabelecer uma faixa de referência de valores para subsidiar a interpretação do TSDx.
ABSTRACT
INTRODUCTION: The 1 mg dexamethasone suppression test (DxST) is widely used to screen Cushing's syndrome (CS) due to its high diagnostic accuracy. CS is an endocrine-metabolic disorder caused by hypercorticism, which is characterized by the absence of cortisol suppression in DxST. OBJECTIVE: To develop a radioimmunoassay (RIA) for the measurement of serum dexamethasone (Dx) to complement DxST. METHODS: Three rabbits were inoculated with dexamethasone-21-hemisuccinate-BSA in order to choose the best antibody. Serum Dx RIA was performed according to RE 899/2003 (Agência Nacional de Vigilância Sanitária [ANVISA]) regulations. Serum samples from 96 volunteers from Universidade Federal de São Paulo (UNIFESP) and Santa Casa de Misericórdia de São Paulo were analyzed, 67 of which were submitted to DxST and 29 were not. There were 12 patients with CS. RESULTS: The Dx antibody chosen showed good specificity. Intra- and interassay CV were < 20 percent with 93.8 percent accuracy and the lowest detection limit was 19.5 ng/dl. Serum Dx concentration was similar among both volunteers and CS patients (absence of cortisol suppression): 205 to 703 ng/dl and 174 to 661 ng/dl (95 percent CI), respectively. Values were undetectable among those that were not submitted to the test. Discussion: The anti-Dx antibody shows high specificity and reliability to quantify serum Dx in DxST. The Dx RIA presented reproducibility and reliability in the determination of serum Dx levels during DxST. CONCLUSION: The current RIA for serum Dx is accurate and reliable, which permits to establish a reference value range to substantiate DxST interpretation.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Hidrocortisona / Radioimunoensaio / Síndrome de Cushing / Especificidade de Anticorpos Tipo de estudo: Estudo diagnóstico / Guia de prática clínica Limite: Animais / Humanos Idioma: Português Revista: J. bras. patol. med. lab Assunto da revista: Patologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Hidrocortisona / Radioimunoensaio / Síndrome de Cushing / Especificidade de Anticorpos Tipo de estudo: Estudo diagnóstico / Guia de prática clínica Limite: Animais / Humanos Idioma: Português Revista: J. bras. patol. med. lab Assunto da revista: Patologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR
...