Your browser doesn't support javascript.
loading
Reprodutibilidade de medidas antropométricas estáticas de graduandos de odontologia e de mochos odontológicos / Reproducibility of static anthropometric measurements of undergraduate dental students and dental stools
Pinelli, Camila; Soares, Débora Dramis; Quirino, Lilian Caldas; Campos, Juliana µlvares Duarte Bonini; Garcia, Patrícia Petromilli Nordi Sasso.
Afiliação
  • Pinelli, Camila; Faculdade de Odontologia de Araraquara. Departamento de Odontologia Social. Araraquara. BR
  • Soares, Débora Dramis; s.af
  • Quirino, Lilian Caldas; s.af
  • Campos, Juliana µlvares Duarte Bonini; Faculdade de Odontologia de Araraquara. Departamento de Odontologia Social. Araraquara. BR
  • Garcia, Patrícia Petromilli Nordi Sasso; Faculdade de Odontologia de Araraquara. Departamento de Odontologia Social. Araraquara. BR
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-614367
Biblioteca responsável: BR1.1
RESUMO

Objetivo:

Avaliar a reprodutibilidade intra-examinador de medidas antropométricas estáticas de graduandos do curso de Odontologia, bem como características e medidas de regulagem de mochos odontológicos por eles utilizados.

Método:

Foram avaliados 40 voluntários e 6 tipos de mochos. Para tomada das medidas antropométicas, os equipamentos utilizados foram cadeira de escritório adaptada, trena flexível com duas hastes adaptadas, dispositivo metálico com ângulo central de 90º, barbante, prancha de madeira retangular medindo 35 x 24 cm, fita isolante e fita crepe. Para padronização do posicionamento da cadeira de escritório adaptada e dos pés dos voluntários foram feitas marcações com fita crepe e isolante no chão. Um fio de barbante foi amarrado na região da cintura de cada voluntário com o objetivo de demarcar a área correspondente à região renal, possibilitando a tomada da medida assento-região renal. As medidas antropométricas observadas foram altura, altura tronco-encefálica, medida sacro-poplítea, largura do quadril, altura poplítea e altura assento-região renal. As características do mocho avaliadas em relação ao assento foram profundidade, largura horizontal e altura mínima/máxima. Em relação ao encosto foram avaliados o ajuste mínimo/máximo de altura. As medidas antropométricas e medidas dos mochos odontológicos foram tomadas por um examinador, em dois momentos distintos, com o intervalo de uma semana entre as avaliações. Para estimar a reprodutibilidade intra-examinador foi utilizado o coeficiente de correlação intra-classe (p).

Resultados:

Verificou-se um excelente resultado de reprodutibilidade para todas as medidas antropométricas tomadas (p=0,99) bem como para os mochos odontológicos avaliados (p=0,99).

Conclusão:

A tomada de medidas antropométricas e dos mochos odontológicos foi reprodutível, podendo ser utilizada com confiança.
ABSTRACT

Objective:

To evaluate the intraexaminer reproducibility of static anthropometric measurements of undergraduate dental students as well as the characteristics and regulating measurements of the dental stools used by them.

Methods:

Forty volunteers and 6 types of dental stools were evaluated. For the anthropometric measurements the employed equipments were an adapted office chair, a flexible measuring tape with two adapted rods, a metallic device with a 90 degree central angle, string, a 35 x 24 cm rectangular wooden board, isolating tape and crepe tape. In order to standardize the position of the adapted office chair and the volunteers' feet, the floor was marked with the isolating and crepe tapes. A string was attached to the waist of each volunteer to mark the area corresponding to the kidney region making it possible to measure the seat-renal region area. The examined anthropometric measurements were height, trunk-cephalic heigh, sacral-popliteal distance (OK?), hip width, popliteal height and the seat-renal region height. The evaluated characteristics of the dental stools relative to the seat were depth, horizontal width and minimum/maximum height. The back of the dental stool was evaluated as for the minimum/maximum height adjustment. The anthropometric and dental stool measurements were obtained by a single examiner at two moments with a 1-week interval between the evaluations. Intra-class correlation coefficient (p) was used to estimate the intraexaminer reproducibility.

Results:

Excellent reproducibility was observed for all anthropometric measurements obtained (p=0.99) as well as for all dental stools evaluated (p=0.99).

Conclusion:

The method used to obtain the anthropometric and dental stools measurements was reproducible and can be used reliably.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Antropometria / Reprodutibilidade dos Testes / Saúde Ocupacional / Odontologia / Ergonomia / Doenças Profissionais Tipo de estudo: Estudo de avaliação Aspecto: Determinantes sociais da saúde Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Odontologia de Araraquara/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Antropometria / Reprodutibilidade dos Testes / Saúde Ocupacional / Odontologia / Ergonomia / Doenças Profissionais Tipo de estudo: Estudo de avaliação Aspecto: Determinantes sociais da saúde Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Odontologia de Araraquara/BR
...