Your browser doesn't support javascript.
loading
Avaliação da frequência e profundidade das compressões torácicas realizadas com o uso de metrônomo / Evaluation of frequency and depth of chest compressions performed with the use of metronome
Fonseca, Ana Helena Isper R. M. da; Fonseca, Filipe Isper R. M. da; Oliveira, Renan Gianotto; Barral, Tatiane Nunes; Gonzalez, Maria Margarita; Timerman, Sergio.
Afiliação
  • Fonseca, Ana Helena Isper R. M. da; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Fonseca, Filipe Isper R. M. da; Universidade Federal de São Paulo. Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Oliveira, Renan Gianotto; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Barral, Tatiane Nunes; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Gonzalez, Maria Margarita; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Timerman, Sergio; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
Rev. Soc. Bras. Clín. Méd ; 10(3)maio-jun. 2012.
Artigo em Português | LILACS | ID: lil-621483
Biblioteca responsável: BR33.1
RESUMO
JUSTIFICATIVA E

OBJETIVOS:

Dispositivos como o metrônomo tem demonstrado aumentar a qualidade da reanimação cardiopulmonar (RCP). O objetivo deste estudo foi avaliar a frequência e a profundidade das compressões torácicas (CT) realizadas com e sem o auxílio do metrônomo.

MÉTODO:

Estudo prospectivo com 44 estudantes de medicina do 1º ano que foram avaliados imediatamente após o curso "Heartsaver DEA". Foi utilizado metrônomo durante o curso,na frequência de 100 por minuto, a fim de auxiliar as CT. Os estudantes realizaram um minuto de CT utilizando o manequim AmbuMan Prolife, parte sem o auxílio do metrônomo (Grupo A) e a outra parte com o auxílio do dispositivo (Grupo B), que permaneceu na frequência de 100 por minuto. Cada avaliação foi filmada e a análise das compressões foi realizada por um instrutor que desconhecia cada grupo.

RESULTADOS:

A média de idade e a porcentagem do sexo masculino no Grupo A e no Grupo B foram de 20,7 ± 3,5 versus 22,5± 1,9 (p = 0,004) e 45,4% versus 54,6% (p = 0,763), respectivamente. Durante um minuto de compressões torácicas, para os Grupos A e B, a média da frequência foi de 110,3 ± 14,2 versus103,6 ± 9,6, respectivamente (p = 0,37) e a média da porcentagem de compressões com profundidade adequada foi de 39,6% ± 34,7 versus 87,4% ± 21,7, respectivamente (p < 0,001).

CONCLUSÃO:

O uso do metrônomo durante o treinamento foi efetivo, demonstrado pela frequência correta obtida em ambos os grupos. A profundidade das compressões foi melhor no grupo que utilizou o metrônomo, talvez pelo fato dos estudantes concentrarem maior atenção na profundidade das compressões já que o dispositivo auxiliava na sua frequência.
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Devices such as metronome have demonstrated to increase the quality of cardiopulmonary resuscitation (CPR). The objective was evaluating the frequency and depth of chest compressions (CC) performed with and without the aid of the metronome.

METHOD:

This prospective study involving 44 medical students coursing the first year, were evaluated immediately after the "Heartsaver AED" course. During the training, a metronome was used to guide the compressions frequency (100 per minute). The students performed CC during one minute, both using AmbuMan Prolife manikins, a group without metronome (Group A) and another group with metronome (Group B) guidance with "tock" prompts for compressions, at rate of 100 per minute. Each session was filmed and analysis of the compressions was performed by an instructor without knowledge of each group.

RESULTS:

The average age and percentage of male gender of Group A and Group B was 20.7 ± 3.5 vs. 22.5 ± 1.9 (p = 0.004) and 45.4% vs. 54.6% (p = 0.763), respectively. During 1 min of CC, considering Group A and Group B, the average rate of compressions was 110.3 ± 14.2 vs. 103.6 ± 9.6, respectively (p= 0.37) and the average percentage of correct depth compression was 39.6% ± 34.7 vs. 87.4% ± 21.7, respectively (p < 0.001).

CONCLUSION:

Using the metronome during training was effective, demonstrated by the frequency of correct CC in both groups. The greatest depth of CC in the group with metronome may be related to less concern with the frequency due to the presence of the stimulus sound and greater focus on appropriate depth of compressions.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Reanimação Cardiopulmonar / Parada Cardíaca / Massagem Cardíaca Tipo de estudo: Estudo observacional / Estudo de rastreamento Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. Soc. Bras. Clín. Méd Assunto da revista: Terapêutica Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR / Universidade de São Paulo/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Reanimação Cardiopulmonar / Parada Cardíaca / Massagem Cardíaca Tipo de estudo: Estudo observacional / Estudo de rastreamento Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. Soc. Bras. Clín. Méd Assunto da revista: Terapêutica Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR / Universidade de São Paulo/BR
...