The use of vancomycin-loaded poly-l-lactic acid and poly-ethylene oxide microspheres for bone repair: an in vivo study
Coraca-Huber, Débora Cristina; Duek, Eliana Aparecida de Rezende; Etchebehere, Maurício; Magna, Luis Alberto; Amstalden, Eliane Maria Ingrid.
Afiliação
  • Coraca-Huber, Débora Cristina; Medical University Innsbruck. Department of Orthopaedic Surgery. Experimental Orthopaedics. AT
  • Duek, Eliana Aparecida de Rezende; Campinas State University. Mechanical Engineering Faculty. BR
  • Etchebehere, Maurício; Campinas State University. Medical Sciences Faculty. Orthopaedic and Traumatology Department. BR
  • Magna, Luis Alberto; Campinas State University. Medical Sciences Faculty. Medical Genetics. BR
  • Amstalden, Eliane Maria Ingrid; Campinas State University. Medical Sciences Faculty. Pathological Anatomy Department. São Paulo. BR
Clinics ; 67(7): 793-798, July 2012. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-645453
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVE:

The aim of this study was to investigate bone repair after the implantation of vancomycin-loaded poly-L-lactic acid/poly-ethylene oxide microspheres compared with vancomycin-unloaded poly-L-lactic acid/poly-ethylene oxide microspheres.

METHODS:

Poly-L-lactic acid/poly-ethylene oxide microspheres were implanted in rat tibiae and evaluated for periods of 2, 4, 8, and 12 days and 4, 8, 16, and 32 weeks. The groups implanted with vancomycin-loaded and vancomycin-unloaded microspheres were compared. Histopathologic (semi-quantitative) and histomorphometric analyses were performed to evaluate the bone formation process.

RESULTS:

During the first period (second day), fibrin and hemorrhaging areas were observed to be replaced by granulation tissue around the microspheres. Woven bone formation with progressive maturation was observed. All of the histopathological findings, evaluated by a semi-quantitative assay and a quantitative analysis (percentage of bone formation), were similar between the two groups.

CONCLUSION:

Vancomycin-loaded poly-L-lactic acid/poly-ethylene oxide microspheres are a good bone substitute candidate for bone repair. Local antibiotic therapy using vancomycin-loaded poly-L-lactic acid/poly-ethylene oxide microspheres should be considered after the microbiological evaluation of its efficacy.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Osteogênese / Polietilenoglicóis / Polímeros / Fraturas da Tíbia / Vancomicina / Substitutos Ósseos / Ácido Láctico Limite: Animais Idioma: Inglês Revista: Clinics Assunto da revista: Medicina Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Áustria / Brasil Instituição/País de afiliação: Campinas State University/BR / Medical University Innsbruck/AT

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Osteogênese / Polietilenoglicóis / Polímeros / Fraturas da Tíbia / Vancomicina / Substitutos Ósseos / Ácido Láctico Limite: Animais Idioma: Inglês Revista: Clinics Assunto da revista: Medicina Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Áustria / Brasil Instituição/País de afiliação: Campinas State University/BR / Medical University Innsbruck/AT
...