Your browser doesn't support javascript.
loading
Comparative study of classic friction among different archwire ligation systems
Queiroz, Gilberto Vilanova; Rino Neto, José; De Paiva, João Batista; Rossi, Jesualdo Luís; Ballester, Rafael Yagüe.
Afiliação
  • Queiroz, Gilberto Vilanova; USP. FO.
  • Rino Neto, José; USP. FO.
  • De Paiva, João Batista; USP. FO.
  • Rossi, Jesualdo Luís; USP. FO.
  • Ballester, Rafael Yagüe; USP. FO.
Dental press j. orthod. (Impr.) ; 17(3): 64-70, May-June 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-646351
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVE:

To describe and compare three alternative methods for controlling classical friction Self-ligating brackets (SLB), special brackets (SB) and special elastomeric ligatures (SEB).

METHODS:

The study compared Damon MX, Smart Clip, In-Ovation and Easy Clip self-ligating bracket systems, the special Synergy brackets and Morelli's twin bracket with special 8-shaped elastomeric ligatures. New and used Morelli brackets with new and used elastomeric ligatures were used as control. All brackets had 0.022 x 0.028-in slots. 0.014-in nickel-titanium and stainless steel 0.019 x 0.025-in wires were tied to first premolar steel brackets using each archwire ligation method and pulled by an Instron machine at a speed of 0.5 mm/minute. Prior to the mechanical tests the absence of binding in the device was ruled out. Statistical analysis consisted of the Kruskal-Wallis test and multiple non-parametric analyses at a 1% significance level.

RESULTS:

When a 0.014-in archwire was employed, all ligation methods exhibited classical friction forces close to zero, except Morelli brackets with new and old elastomeric ligatures, which displayed 64 and 44 centiNewtons, respectively. When a 0.019 x 0.025-in archwire was employed, all ligation methods exhibited values close to zero, except the In-Ovation brackets, which yielded 45 cN, and the Morelli brackets with new and old elastomeric ligatures, which displayed 82 and 49 centiNewtons, respectively.

CONCLUSIONS:

Damon MX, Easy Clip, Smart Clip, Synergy bracket systems and 8-shaped ligatures proved to be equally effective alternatives for controlling classical friction using 0.014-in nickel-titanium archwires and 0.019 x 0.025-in steel archwires, while the In-Ovation was efficient with 0.014-in archwires but with 0.019 x 0.025-in archwires it exhibited friction that was similar to conventional brackets with used elastomeric ligatures.


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Inglês Revista: Dental press j. orthod. (Impr.) Assunto da revista: Ortodontia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Inglês Revista: Dental press j. orthod. (Impr.) Assunto da revista: Ortodontia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil
...