Your browser doesn't support javascript.
loading
Ecocardiografia transesofágica em anestesiologia: caracterização do perfil de uso em um hospital terciário / Transesophageal echocardiography in anesthesiology: characterization of use profile in a tertiary hospital / Ecocardiografía transesofágica en anestesiología: caracterización del perfil de uso en un hospital terciario
Silva, Alexander Alves da; Segurado, Arthur; Kimachi, Pedro Paulo; Silva, Enis Donizete; Goehler, Fernando; Gregory, Fabio; Simões, Claudia.
Afiliação
  • Silva, Alexander Alves da; São Paulo Serviços Médicos de Anestesia.
  • Segurado, Arthur; São Paulo Serviços Médicos de Anestesia.
  • Kimachi, Pedro Paulo; São Paulo Serviços Médicos de Anestesia.
  • Silva, Enis Donizete; São Paulo Serviços Médicos de Anestesia.
  • Goehler, Fernando; São Paulo Serviços Médicos de Anestesia.
  • Gregory, Fabio; São Paulo Serviços Médicos de Anestesia.
  • Simões, Claudia; São Paulo Serviços Médicos de Anestesia.
Rev. bras. anestesiol ; 62(5): 644-653, set.-out. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-649546
Biblioteca responsável: BR1.1
RESUMO
JUSTIFICATIVA E

OBJETIVO:

Desde sua introdução, na década de 1980, a ecocardiografia transesofágica (ETE) não só ganhou popularidade como também passou por grandes avanços tecnológicos e atualmente constitui-se numa ferramenta extremamente valiosa no período intraoperatório. No Brasil ainda não há dados publicados sobre o perfil de seu uso no período intraoperatório por anestesiologistas. O objetivo deste trabalho foi descrever o perfil de uso da ETE no intraoperatório por Serviço de Anestesiologia em um hospital privado de nível terciário. PACIENTES E

MÉTODOS:

Estudo retrospectivo feito através da coleta de dados das fichas preenchidas em todos os casos em que o paciente foi monitorado com a ETE. A monitoração foi aplicada nos pacientes enquadrados nas classes I e II de acordo com a Sociedade Americana de Ecocardiografia e que não apresentassem contraindicação ao exame. No fim do procedimento, após a conclusão do exame, uma anotação na ficha classificou a monitoração quanto à sua utilidade no período intraoperatório em três grupos grupo 1 - a ETE não interferiu na conduta cirúrgica ou anestésica; grupo 2 - a ETE motivou mudança na conduta anestésica quanto à administração de volume, introdução e/ou modificação de drogas vasoativas (aqui a ETE gerou a mudança de conduta anestésica em conjunto com os outros monitores, porém sendo ela o fator decisivo); grupo 3 - a ETE levou a mudança de conduta ou revisão do procedimento cirúrgico.

RESULTADOS:

De janeiro de 2009 a janeiro de 2011, 164 ETE intraoperatórias foram feitas em nosso serviço, sendo 41 pacientes pediátricos e 123 adultos. Em todos os pacientes o exame foi feito com sucesso e não houve problemas com relação à introdução da sonda transesofágica. No grupo dos pacientes pediátricos, 10 ficaram no grupo 1 (24,4%), 27 no grupo 2 (65,8%) e quatro no grupo 3 (9,8%). Entre os adultos, o grupo 1 ficou com 38 pacientes (30,9%), o grupo 2 com 81 (65,9%) e o grupo 3 com 4 (3,2%).

CONCLUSÕES:

Apesar da pequena casuística quando comparada à literatura mundial e das limitações deste estudo, houve concordância com outros relatos com relação às mudanças de conduta cirúrgico-anestésica baseadas na ETE intraoperatória. Os dados também sugerem fortemente que a ecocardiografia transesofágica constitui-se em ferramenta extremamente útil para a monitoração de pacientes de alto risco cardiovascular, mesmo quando submetidos a cirurgia não cardíaca. Maiores estudos originados no nosso país são necessários, pois não há na literatura outros trabalhos que definam o perfil de uso ou mesmo que estabeleçam claramente como vem sendo usada a ETE em nosso meio.
ABSTRACT
BACKGROUND AND

OBJECTIVE:

Since its introduction in the 80s, transesophageal echocardiography (TEE) not only gained popularity but also experienced great advances in technology and currently it is an extremely valuable tool in the intraoperative period. In Brazil, there are no published data on the profile of its use in the intraoperative period by anesthesiologists. The objective of this study was to describe the use of intraoperative TEE in an Anesthesiology Service in a tertiary private hospital. PATIENTS AND

METHODS:

Retrospective study from completed medical charts in all cases where the patient was monitored with TEE. Monitoring was applied in patients classified as I-II according to the American Society of Echocardiography and presenting no contraindication to the examination. At the end of procedure, after examination, a note on the chart classified monitoring according to its usefulness in the intraoperative period into three groups group 1, no interference of TEE in anesthetic or surgical approach; group 2, TEE prompted change in anesthetic approach regarding the administration of volume, introduction and/or modification of vasoactive drugs (here, TEE generated change of anesthetic approach in conjunction with other monitors, but it was the deciding factor); group 3, TEE led to a change in approach or review of surgical procedure performed.

RESULTS:

From January 2009 to January 2011, 164 intraoperative TEE were performed in our service, with 41 pediatric and 123 adult patients. In all patients, the test was successful and there were no problems regarding the introduction of transesophageal tube. In pediatric sample, group I had 10 patients (24.4%), group II had 27 patients (65.8%), and group III had 4 patients (9.8%). Among adults, group I had 38 patients (30.9%), group II had 81 patients (65.9%), and group III had 4 patients (3.2%).

CONCLUSION:

Despite this small sample size compared to the literature, and the limitations of this study, there was agreement with other reports related to changes in anesthetic-surgical approach based on intraoperative TEE. Our data also strongly suggest that transesophageal echocardiography is an extremely useful tool for monitoring patients at high cardiovascular risk, even when undergoing noncardiac surgery. Larger studies conducted in our country are needed, as there are no other studies in literature defining the use profile of TEE or even clearly setting out how it has been used in our field.
RESUMEN
JUSTIFICATIVA Y

OBJETIVOS:

Desde su introducción en la década de 1980, la ecocardiografía transesofágica (ETE) no solo obtuvo popularidad, sino que también llegó a alcanzar grandes avances tecnológicos y actualmente es una herramienta extremadamente valiosa en el período intraoperatorio. En Brasil todavía no existen datos publicados sobre el perfil de su uso en el período intraoperatorio por parte de los anestesiólogos. El objetivo de este trabajo, fue describir el perfil de uso de la ETE en el intraoperatorio por nuestro Servicio de Anestesiología en un hospital privado de nivel terciario. PACIENTES Y

MÉTODOS:

Estudio retrospectivo hecho por medio de la recolección de datos de las fichas rellenadas en todos los casos en que el paciente estuvo monitorizado con la ETE. La monitorización fue aplicada a los pacientes encuadrados en las clases I y II de acuerdo con la Sociedad Norteamericana de Ecocardiografía y que no tenían ninguna contraindicación para el examen. Al finalizar el procedimiento, y después de la conclusión del examen, una anotación en la ficha clasificó la monitorización en cuanto a su utilidad en el período intraoperatorio en tres grupos grupo 1 - la ETE no interfirió en la conducta quirúrgica o anestésica; grupo 2 - la ETE motivó un cambio en la conducta anestésica en cuanto a la administración de volumen, introducción y/o modificación de fármacos vasoactivos (aquí la ETE generó el cambio de conducta anestésica en conjunto con los otros monitores, pero siendo ella el factor decisivo); grupo 3 - la ETE conllevó al cambio de conducta o revisión del procedimiento quirúrgico.

RESULTADOS:

De enero de 2009 a enero de 2011, 164 ETE intraoperatorias se realizaron en nuestro servicio, siendo 41 pacientes pediátricos y 123 adultos. En todos los pacientes el examen se hizo con éxito y no hubo problemas con relación a la introducción de la sonda transesofágica. En el grupo de los pacientes pediátricos, 10 permanecieron en el grupo 1 (24,4%), 27 en el grupo 2 (65,8%) y cuatro en el grupo 3 (9,8%). Entre los adultos, el grupo 1 quedó con 38 pacientes (30,9%), el grupo 2 con 81 (65,9%) y el grupo 3 con 4 (3,2%).

CONCLUSIONES:

Pese a que nuestra pequeña casuística fue comparada con la literatura mundial y se vieron las limitaciones de este estudio, sí que hubo una concordancia con otros relatos en la literatura con relación a los cambios de conducta quirúrgico-anestésica con base en la ETE intraoperatoria. Nuestros datos también sugieren firmemente que la ecocardiografía transesofágica es una herramienta extremadamente útil para la monitorización de los pacientes de alto riesgo cardiovascular, incluso cuando están sometidos a la cirugía no cardíaca. Más estudios originados en nuestro país se hacen necesarios, porque no hay en la literatura otros trabajos que definan el perfil de uso o incluso que establezcan claramente cómo ha venido siendo usada la ETE en nuestro medio.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Ecocardiografia Transesofagiana / Cuidados Intraoperatórios / Anestesia Tipo de estudo: Estudo observacional / Fatores de risco Limite: Idoso / Criança / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. anestesiol Assunto da revista: Anestesiologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Ecocardiografia Transesofagiana / Cuidados Intraoperatórios / Anestesia Tipo de estudo: Estudo observacional / Fatores de risco Limite: Idoso / Criança / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. anestesiol Assunto da revista: Anestesiologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil
...