Your browser doesn't support javascript.
loading
Evaluación del método dilución neutralización aplicado a un desinfectante según la Norma Técnica Colombiana 5473 de 2007 / Assessment of the dilution-neutralization method with a disinfectant according to the Colombian Technical Norm 5473 of 2007 / Avaliação do método de diluição-neutralização aplicado num desinfectante segundo a "Norma Técnica Colombiana 5473 de 2007"
Arias-Palacios, Janeth; Hernandez-Esquivel, Libardo; Marín-Díaz, Juan Carlos; Navarro-Peña, Natalia; Santos-Arévalo, Natalia.
Afiliação
  • Arias-Palacios, Janeth; Pontificia Universidad Javeriana. Facultad de Ciencias. Departamento de Microbiología. Grupo de Biotecnología Ambiental e Industrial. Bogotá, D.C.. CO
  • Hernandez-Esquivel, Libardo; Laboratorios Vicar Farmacéutica. Bogotá, D.C.. CO
  • Marín-Díaz, Juan Carlos; Pontificia Universidad Javeriana. Facultad de Ciencias. Carrera de Microbiología Industrial. Bogotá, D.C.. CO
  • Navarro-Peña, Natalia; Pontificia Universidad Javeriana. Facultad de Ciencias. Carrera de Microbiología Industrial. Bogotá, D.C.. CO
  • Santos-Arévalo, Natalia; Pontificia Universidad Javeriana. Facultad de Ciencias. Carrera de Microbiología Industrial. Bogotá, D.C.. CO
Univ. sci ; 17(1): 72-81, Jan.-Apr. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-650128
Biblioteca responsável: CO332
RESUMEN
Objetivo. Evaluar el método de dilución neutralización propuesto en la Norma Técnica Colombiana 5473 de 2007, mediante la utilización de un desinfectante en gel a base de alcohol. Materiales y métodos. El ensayo se efectuó utilizando Pseudomonas aeruginosa ATCC 15442, Staphylococcus aureus ATCC 6538 y Enterococcus hirae ATCC 10541, como microorganismos de ensayo. Las temperaturas del estudio fueron 20±1°C como temperatura obligatoria y 36±1°C y se emplearon cuatro tiempos de contacto entre el desinfectante y los microorganismos evaluados (0, 2, 5 y 10 minutos). El método fue realizado bajo condiciones limpias (0,3 g/L de albumina de suero bovino) y sucias (3g/L de albumina de suero bovino y 3g/L de eritrocitos de oveja). Resultados. La implementación del método arrojó resultados precisos en cada una de las seis repeticiones realizadas en el ensayo. Los resultados obtenidos demostraron una reducción logarítmica superior a cinco, evidenciando la actividad bactericida ejercida por el desinfectante frente a los microorganismos control. El establecimiento de las condiciones experimentales y de la metodología demostró no incidir negativamente en el crecimiento de cada una de las cepas. Igualmente, el neutralizante utilizado no inhibió el desarrollo de los organismos de ensayo. Conclusiones. Se verificó el método mediante el cumplimiento de los límites establecidos por la norma. Los resultados sugieren que el método evaluado mediante la implementación del protocolo establecido en la Norma Técnica Colombiana 5473 de 2007, permite evaluar la eficacia de un desinfectante bajo condiciones experimentales escogidas y controladas.
ABSTRACT
Objective. Evaluate the dilution-neutralization method proposed in the Colombian Technical Norm 5473/07, by using a gel, alcohol-based disinfectant. Materials and methods. This study was done using Pseudomonas aeruginosa ATCC 15442, Staphylococcus aureus ATCC 6538, and Enterococcus hirae ATCC 10541 as the assay microorganisms. The study was carried out at 20±1°C as obligatory temperature and additionally at 36±1°C. Four contact times between microorganisms and the disinfectant were evaluated (0, 2, 5 and 10 minutes). The assay was done both under clean conditions (0.3 g/L of bovine serum albumin), and unclean conditions (3 g/L of bovine serum albumin and 3g/L of sheep erythrocytes). Results. The implementation of this method produced precise results in all of the six repetitions used during the assay. The obtained results demonstrated a logarithmic reduction higher than five, demonstrating the bactericidal activity exerted by the disinfectant on the control microorganisms. The established experimental conditions and methodology did not affect negatively the growth of any of the strains of microorganisms. Similarly, the neutralizing used did not inhibit the development of the microorganisms of the assay. Conclusions. The method was verified by means of the fulfillment of the limits set by the rule. Our results suggest that the method evaluated by means of the implementation of the protocol established in the Colombian Technical Norm 5473/07, allows evaluating the effectiveness of a disinfectant under selected and controlled experimental conditions.
RESUMO
Objetivo. Avaliar o método de diluição-neutralização proposto na "Norma Técnica Colombiana 5473 de 2007", pela utilização de um desinfectante gel à base de álcool. Materiais e métodos. O teste foi realizado utilizando Pseudomonas aeruginosa ATCC 15442, Staphylococcus aureus ATCC 6538 e Enterococcus hirae ATCC 10541, como microrganismos de ensaio. As temperaturas do estudo foram de 20 ± 1°C como temperatura requerida e 36 ± 1°C e foram utilizados quatro tempos de contacto entre o desinfectante e os microorganismos avaliados (0, 2, 5 e 10 minutos). O método foi realizado sob condições limpas (0,3 g/L de albumina sérica bovina) e sujas (3g/L de albumina sérica bovina e 3g/L de eritrócitos de carneiro). Resultados. A implementação do método produz resultados precisos sobre cada uma das seis repetições realizadas no ensaio. Os resultados mostraram uma redução logarítmica superior a cinco, o que evidencia a actividade bactericida exercida pelo desinfectante contra os microrganismos control. O estabelecimento das condições experimentais e da metodologia provou não incidir negativamente no crescimento de cada uma das cepas. Similarmente, o neutralizador utilizado não inibiu o desenvolvimento dos organismos do experimento. Conclusões. Verificou-se o método através do cumprimento dos limites estabelecidos pela norma. Os resultados sugerem que o método avaliado através da aplicação do protocolo estabelecido pela "Norma Técnica Colombiana 5473 de 2007", permite avaliar a eficácia de um desinfectante em condições experimentais seleccionadas e controladas.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.3: Acabar com as doenças tropicais negligenciadas e combater as doenças transmissíveis / Meta 3.9: Reduzir o número de mortes por produtos químicos perigosos e contaminação do ar e água do solo Base de dados: LILACS Assunto principal: Desinfecção / Desinfetantes País/Região como assunto: América do Sul / Colômbia Idioma: Inglês Revista: Univ. sci Assunto da revista: Medicina Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Laboratorios Vicar Farmacéutica/CO / Pontificia Universidad Javeriana/CO
Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.3: Acabar com as doenças tropicais negligenciadas e combater as doenças transmissíveis / Meta 3.9: Reduzir o número de mortes por produtos químicos perigosos e contaminação do ar e água do solo Base de dados: LILACS Assunto principal: Desinfecção / Desinfetantes País/Região como assunto: América do Sul / Colômbia Idioma: Inglês Revista: Univ. sci Assunto da revista: Medicina Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Laboratorios Vicar Farmacéutica/CO / Pontificia Universidad Javeriana/CO
...