Your browser doesn't support javascript.
loading
A methodology to standardize the evaluation of root canal instrumentation using cone beam computed tomography
Flores, Cláudia Bohrer; Machado, Patrícia; Montagner, Francisco; Gomes, Brenda Paula Figueiredo de Almeida; Dotto, Gustavo Nogara; Schmitz, Marcia da Silva.
Afiliação
  • Flores, Cláudia Bohrer; Federal University of Santa Maria. Santa Maria. BR
  • Machado, Patrícia; Federal University of Santa Maria. Santa Maria. BR
  • Montagner, Francisco; Federal University of Rio Grande do Sul. Department of Conservative Dentistry. Endodontic Division. Porto Alegre. BR
  • Gomes, Brenda Paula Figueiredo de Almeida; University of Campinas. Piracicaba Dental School. Department of Conservative Dentistry. Piracicaba. BR
  • Dotto, Gustavo Nogara; Federal University of Santa Maria. Department of Stomatology. Endodontic Division. Santa Maria. BR
  • Schmitz, Marcia da Silva; Federal University of Santa Maria. Department of Stomatology. Endodontic Division. Santa Maria. BR
Braz. j. oral sci ; 11(2): 84-87, abr.-jun. 2012. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-654825
Biblioteca responsável: BR218.1
ABSTRACT
The evaluation of root canal instrumentation is important to observe the action of endodontic instrumentsin the root canal walls. Aim: This study introduces a method to standardize the acquisition of imagesbefore and after preparing root canals by using cone-beam computed tomography (CBCT). Methods:Sixteen mandibular molars were included in acrylic resin blocks. Samples were inserted in a stablewood box, which was filled with plaster and served as a guide to reinsert the samples. The apparatuswas used for the CBCT examination before and after cervical flaring of root canals. The softwareIcatVision® was used to equalize the images before and after instrumentation with two computersoperating at the same time. The measurements between root canal center and the furcation areawere determined. The statistical analysis was performed using the t-test for paired samples (á=0.05).Results: The values for dentin thickness in the risk zone before and after root canal flaring withGates-Gliden drills were 1.096 (± 0.27) mm and 0.742 (± 0.24) (p<0.01), respectively. Conclusions:The proposed method assures the same positioning of the samples before and after root canalpreparation. It is extremely important, as any mesiodistal or buccolingual movement can producea different topogram for comparison procedures.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Processamento de Imagem Assistida por Computador / Anatomia Transversal / Endodontia / Tomografia Computadorizada de Feixe Cônico Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Rio Grande do Sul/BR / Federal University of Santa Maria/BR / University of Campinas/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Processamento de Imagem Assistida por Computador / Anatomia Transversal / Endodontia / Tomografia Computadorizada de Feixe Cônico Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Rio Grande do Sul/BR / Federal University of Santa Maria/BR / University of Campinas/BR
...