Your browser doesn't support javascript.
loading
Avaliação clínica em curto prazo do sistema de Cone Morse e plataforma reduzida em prótese sobre implantes do tipo protocolo: estudo piloto randomizado controlado / Short-term clinical evaluation of morse taper and platform switching in implant-supported protocol-type prosthesis: pilot randomized controlled study
Camacho, Fausto Maurício Tinajero; Sakakura, Celso Eduardo; Mera, Mario Francisco Muñoz; Esteves, Jônatas Caldeira; Ribeiro, Fernando Salimon; Pontes, Ana Emília Farias.
Afiliação
  • Camacho, Fausto Maurício Tinajero; Fundação Educacional de Barretos. Barretos. BR
  • Sakakura, Celso Eduardo; Fundação Educacional de Barretos. Barretos. BR
  • Mera, Mario Francisco Muñoz; Fundação Educacional de Barretos. Barretos. BR
  • Esteves, Jônatas Caldeira; Universidade Estadual Paulista. Faculdade de Odontologia. Departamento de Cirurgia e Diagnóstico. Araraquara. BR
  • Ribeiro, Fernando Salimon; Fundação Educacional de Barretos. Barretos. BR
  • Pontes, Ana Emília Farias; Fundação Educacional de Barretos. Barretos. BR
Rev. odontol. UNESP (Online) ; 41(4): 247-253, jul.-ago. 2012. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-667025
Biblioteca responsável: BR39.2
RESUMO

Introdução:

Implantes dentários com conexões do tipo Cone Morse combinados a plataforma reduzida podem minimizar a reabsorção da crista óssea perimplantar. Entretanto, ainda não está claro se seu uso resultaria também em uma melhor manutenção da altura dos tecidos moles, o que poderia interferir no resultado estético final.

Objetivo:

Este estudo teve o objetivo de avaliar os tecidos moles ao redor de implantes dentários com Cone Morse, comparativamente àqueles com hexágono interno, em pacientes com edentulismo total, submetidos a carregamento imediato com prótese total fixa inferior. Material e

método:

Dez pacientes tiveram quatro implantes instalados na mandíbula, dois com Cone Morse e dois com hexágono interno, sendo a prótese instalada 72 horas após esse procedimento. Três meses depois, o índice de placa, o índice de sangramento à sondagem, a profundidade de sondagem, a posição do tecido marginal e o nível de inserção relativo foram avaliados pelos testes t e Wilcoxon (α = 5%).

Resultado:

Nos implantes com Cone Morse, a profundidade de sondagem foi significantemente menor do que naqueles com hexágono interno (p = 0,02). Nos implantes com Cone Morse, o tecido marginal estava em média 0,6 mm coronal à junção prótese-conector protético, enquanto que, nos implantes com hexágono interno, o tecido marginal esteve em média 0,4 mm apical à junção prótese-componente protético (p = 0,001). Adicionalmente, a inserção clínica nos implantes com Cone Morse estava em um nível mais coronal do que naqueles com hexágono interno (p = 0,02).

Conclusão:

Nas condições estudadas, os implantes do sistema Cone Morse se mostraram mais eficientes em manter a altura dos tecidos moles perimplantares do que os implantes do sistema hexágono interno.
ABSTRACT

Introduction:

Dental implants with Morse taper connection combined with platform switching may minimize peri-implant crestal bone resorption. However, it remains unclear whether its use would better maintain soft tissue height, which could interfere with the esthetic outcome.

Objective:

The aim of this study was to evaluate the soft tissue around dental implants with Morse taper, compared to implants with internal hexagon connection, in patients with total edentulism who were submitted to immediate loading with lower fixed complete dentures. Material and

method:

Ten patients had four implants installed in the mandible, two with Morse taper and two with internal hexagon; and a provisional prosthesis was installed 72 hours afterward. Three months later, plaque index, bleeding on probing index, probing depth, position of soft tissue margin, and relative attachment level.

Result:

In implants with Morse taper, probing depth was significantly lower than in those with internal hexagon (p = 0.02). In Morse taper implants, the soft tissue margin was positioned 0.6 mm coronal to the prosthesis-abutment junction; in internal hexagon implants, marginal tissue was 0.4 mm apical to the prosthesis-abutment junction (p = 0.001). Additionally, in the Morse taper implants, the attachment level was at a more coronal level than in the internal hexagon implants (p = 0.02).

Conclusion:

Under the conditions studied, implants with the Morse taper connection were more effective in maintaining the height of peri-implant soft tissue than implants with internal hexagon.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Reabsorção Óssea / Implantes Dentários / Prótese Total / Processo Alveolar / Prótese Ancorada no Osso / Gengiva Tipo de estudo: Ensaio clínico controlado / Guia de prática clínica Idioma: Português Revista: Rev. odontol. UNESP (Online) Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Educacional de Barretos/BR / Universidade Estadual Paulista/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Reabsorção Óssea / Implantes Dentários / Prótese Total / Processo Alveolar / Prótese Ancorada no Osso / Gengiva Tipo de estudo: Ensaio clínico controlado / Guia de prática clínica Idioma: Português Revista: Rev. odontol. UNESP (Online) Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Educacional de Barretos/BR / Universidade Estadual Paulista/BR
...