Efecto del termociclado y el acondicionamiento en el sellado de una resina microhibrida / Efect of thermocycling and the kind of conditioning in the sealing of a microhybrid resin
Simancas Pereira, Yanet; Rosales Leal, Juan; Vallejo Bolaños, Encarnación.
Afiliação
  • Simancas Pereira, Yanet; Universidad de Los Andes. Facultad de Odontología. Departamento de Odontología Preventiva y Social. Caracas. VE
  • Rosales Leal, Juan; Universidad de Granada. Departamento de Estomatología. Granada. ES
  • Vallejo Bolaños, Encarnación; Universidad de Granada. Departamento de Estomatología. Granada. ES
Acta odontol. venez ; 50(2)2012. tab
Artigo em Espanhol | LILACS | ID: lil-676728
Biblioteca responsável: VE1.1
RESUMEN
Evaluar el efecto del termociclado y el tipo de acondicionamiento en el sellado de una resina microhibrida. 20 terceros molares sanos se dividieron en dos grupos en función del sistema adhesivo. Estos a su vez se subdividieron en dos de acuerdo al termociclado. Se realizaron cavidades clase V y posteriormente se obturaron con el sistema adhesivo y el material utilizado. Los dientes se termociclaron en agua y se colocaron en solución de fuscina al 0.5% durante 24 horas. Se evaluó la microfiltración del material utilizado. El grupo Esthet-X-Xeno no presentó microfiltración, en contraste con el grupo Esthet-X-P&B NT quien presentó una media de 32 m (1000 Ciclos) en la pared oclusal y 654 m (1000 ciclos) en la pared gingival. Al realizar ANOVA y test DSH de Tukey entre la variable microfiltración y termociclado indican que el termociclado influye en la capacidad de sellado del material, siendo los valores estadísticamente significativos entre las muestras que fueron sometidas a termociclado y las que no fueron sometidas a termociclado (p=0,0000). Asimismo, ANOVA y test post hoc de comparaciones múltiples Tukey entre la variable microfiltración y tipo de acondicionamiento indican que existen diferencias estadísticamente significativas entre las dos variables, observándose que el grupo Esthet-X usado con adhesivo Xeno III no presento niveles de microfiltración y los mejores promedios de sellado, tanto para la pared oclusal como en la pared gingival al ser comparados con el grupo Esthet-X- Prime&Bond p=0,0000). El termociclado y el acondicionamiento de la superficie influyen en la capacidad de sellado de la resina microhibrida. El termociclado disminuye la capacidad de sellado con mayor tendencia en el margen gingival. Usar un adhesivo autograbador con una resina microhíbrida permite el completo sellado.
ABSTRACT
To evaluate the effect of thermocycling and the kind of conditioning in the sealing of a microhybrid resin. 20 healthy third molars were divided in two groups in terms of the adhesive system. At the same time, those were divided in two groups in terms of thermocycling. Class V cavities were made and then filled with the adhesive system and the used material. Teeth were thermocycled in water and stored in fuchsin solution at 0.5% during 24 hours. Microleakage of the used materials was evaluated. The Esthet-X-Xeno group did not show microleakage, opposite to the Esthet-X-P&B NT group which got a mean of 32 m (1000 Cycles) in the occlusal wall and a mean of 654 m (1000 cycles) in the gingival wall. The ANOVA and Tukey's DSH between the variable microleakage and thermocycling they indicate that the thermocycling influences in the capacity of seal of the material, being the significant statistics between the samples that were put under thermocycling and those that were not put under thermocycling (p=0,0000). Also, the ANOVA and Tukey's DSH between the variable microleakage and type of preparation indicate that statistically significant differences between the two variables exist, being observed that the Esthet-X group used with adhesive Xeno III presents smaller values of microleakage and the best averages of seal, as much for the oclusal wall as in compared the gingival wall the being with the group Esthet-X- Prime& Bond (p=0,0000). The thermociclyng and conditioning of the surface have an influence on the sealing ability of the microhybrid resin. Thermocycled diminishes the sealing ability with a higher trend in the gingival margin. Using a selfetching adhesive with a microhybrid resin allow complete sealing.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Micropeneiramento / Cárie Dentária / Cimentos de Ionômeros de Vidro Tipo de estudo: Estudo de avaliação Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Acta odontol. venez Assunto da revista: Medicina Bucal / Odontologia / Sa£de Bucal Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Colômbia / Espanha Instituição/País de afiliação: Universidad de Granada/ES / Universidad de Los Andes/VE
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Micropeneiramento / Cárie Dentária / Cimentos de Ionômeros de Vidro Tipo de estudo: Estudo de avaliação Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Acta odontol. venez Assunto da revista: Medicina Bucal / Odontologia / Sa£de Bucal Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Colômbia / Espanha Instituição/País de afiliação: Universidad de Granada/ES / Universidad de Los Andes/VE
...