Your browser doesn't support javascript.
loading
Avaliação do desempenho visual da lente intraocular difrativa multifocal - Zeiss AT Lisa 809 MTM / Visual outcomes of the diffractive multifocal intraocular lens - Zeiss AT Lisa 809MTM
Vianna, Lucas Monferrari Monteiro; Oliveira, Filipe de; Pedro, Abujamra; Jung, Liang; Brenner, Luis Felipe; Yogi, Milton.
Afiliação
  • Vianna, Lucas Monferrari Monteiro; Universidade Federal de São Paulo. São Paulo. BR
  • Oliveira, Filipe de; Universidade Federal de São Paulo. São Paulo. BR
  • Pedro, Abujamra; Universidade Federal de São Paulo. São Paulo. BR
  • Jung, Liang; Universidade Federal de São Paulo. São Paulo. BR
  • Brenner, Luis Felipe; Universidade Federal de São Paulo. São Paulo. BR
  • Yogi, Milton; Universidade Federal de São Paulo. São Paulo. BR
Rev. bras. oftalmol ; 73(2): 81-85, Mar-Apr/2014. tab, graf
Artigo em Português | LILACS | ID: lil-718429
Biblioteca responsável: BR1.2
RESUMO
Objetivo: Avaliar a função visual dos pacientes com implante bilateral da LIO multifocal difrativa AT-Lisa 809 MTM por meio dos exames de acuidade visual com e sem correção óptica, curva de sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF39). Métodos: Estudo clínico, prospectivo e de intervenção, que avaliou os resultados de 20 olhos de 10 pacientes, submetidos à facoemulsificação e implante de LIO, entre fevereiro e junho de 2012. Resultados: A ametropia residual média pós-operatória foi de 0,05 ± 0,42 (-0,75 a +1,25 D) dioptrias esféricas e -0,30 ± 0,42 (0 a -1,25 D) dioptrias cilíndricas. Na curva de desenfoque mono e binocular, a melhor acuidade visual média obtida com 0.00 D de desenfoque (AV de longe). O segundo pico foi obtido com desenfoque de -3,00 D, o que equivale à visão de perto a 33 cm. Entre esses picos, observamos uma perda de desempenho visual, com desenfoque de -2,00 D, que equivale a visão intermediária a 50 cm. A sensibilidade ao contraste foi similar aos relatados na literatura com este tipo de LIO, tanto com quanto sem ofuscamento, e é mostrada em gráficos. O questionário de função visual (VFQ-39) teve valor médio de 91,91 +- 6,82. Conclusão: A LIO multifocal difrativa AT-Lisa 809MTM (Carl Zeiss Meditec Company - Alemanha) apresentou resultados condizentes com a literatura quando avaliada pelos exames de acuidade visual com e sem correção óptica, sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF 39). .
ABSTRACT
Purpose: To evaluate the visual function of patients with bilateral implantation of multifocal diffractive IOL AT Lisa 809MTM by visual acuity with and without correction, contrast sensitivity curve, defocus curve and visual function questionnaire (39 VQF). Methods: Interventional clinical prospective study, which evaluated the results of 20 eyes of 10 patients who underwent phacoemulsification and IOL implantation between february and june 2012. Results: The average of residual postoperative ametropia was 0.05 ± 0.42 (-0.75 to +1.25 D) spherical diopters and -0.30 ± 0.42 (0 to -1.25 D) cylindrical diopters. In the mono and binocular defocus curve, the best visual acuity was obtained with 0.00 D of defocus (far VA). The second peak was obtained with -3.00 D (near vision at 33 cm) and among these peaks, it was observed a loss of visual performance with -2.00 D, which corresponds to intermediate vision at 50 cm. Contrast sensitivity was similar to those reported in the literature with this type of IOL, both with and without glare, and is shown in the figures. The visual function questionnaire (VFQ-39) had a mean value of 91.91 + - 6.82. Conclusion: The diffractive multifocal IOL-AT LISA 809M presented results consistent with the literature as measured by tests of visual acuity with and without optical correction, contrast sensitivity curve, defocus curve and visual function questionnaire (39 VQF). .
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Implante de Lente Intraocular / Lentes Intraoculares Multifocais Tipo de estudo: Estudo observacional Limite: Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Implante de Lente Intraocular / Lentes Intraoculares Multifocais Tipo de estudo: Estudo observacional Limite: Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR
...