Your browser doesn't support javascript.
loading
Determinación de plomo en lápices labiales de diferentes marcas comercializados en Lima / Determination of plumb in lip pencils of different commercial marks in Lima
Alvarado Y, µngel; Loja H, Berta; Pineda P, Mario; Inocente C, Miguel; Castañeda C, Benjamín.
Afiliação
  • Alvarado Y, µngel; Universidad de San Martín de Porres. Facultad de Medicina Humana. Lima. PE
  • Loja H, Berta; Universidad de San Martín de Porres. Facultad de Medicina Humana. Instituto de Investigación. Lima. PE
  • Pineda P, Mario; Universidad de San Martín de Porres. Facultad de Medicina Humana. Instituto de Investigación. Lima. PE
  • Inocente C, Miguel; Universidad de San Martín de Porres. Facultad de Medicina Humana. Instituto de Investigación. Lima. PE
  • Castañeda C, Benjamín; Universidad de San Martín de Porres. Facultad de Medicina Humana. Instituto de Investigación. Lima. PE
Horiz. méd. (Impresa) ; 14(2): 18-21, jul. 2014. tab, graf
Artigo em Espanhol | LILACS, LIPECS | ID: lil-728036
Biblioteca responsável: PE1.1
RESUMEN

Objetivo:

Determinar la presencia de plomo en los lápices labiales de diferentes marcas que se expenden en la ciudad de Lima. Material y

Método:

Se utilizó 24 lápices labiales de cinco marcas comerciales operantes en Perú, procedentes del centro comercial Capón en Lima. La presencia de plomo se determinó por el método de espectrofotometría de absorción atómica con horno de grafito. Para la validación estadística, se determinó la media y la desviación estándar.

Resultados:

Se encontró mayor contenido de plomo en las marcas LAL-04-YHBC (3,02 ppm), LAL-05-BALOE (2,10 ppm), LAL- 02-RW (1,55 ppm) y LAL-03-VCYH (1,22 ppm); contrastada con una marca poco conocida,de código LAL-01-CHOCO PLUSII en la que no se detectó plomo.

Conclusiones:

De los lápices labiales estudiados, cuatro de ellos superaron los valores permisibles de plomo (0,1 ppm), que es un valor referencial para caramelos.
ABSTRACT

Objective:

To determine the presence of lead in lipsticks from different brands that are sold in the city of Lima. Material and

Methods:

24 lipsticks of five different trademarks were used, from the shopping center in Lima Capon. The presence of lead was determined by the method of atomic absorption spectrophotometry with graphite furnace. For statistical validation, the mean and standard deviation was determined.

Results:

The highest lead content was found in the LAL -04 - YHBC (3.02 ppm) , LAL -05 - BALOE (2.10 ppm) , LAL -02 -RW (1.55 ppm) and LAL -03 marks - VCYH (1.22 ppm ) ; contrasted with a little known brand , LAL -01- CHOCO PLUSII code where no lead was detected.

Conclusions:

Of the studied lipsticks, four exceeded the permissible values of lead (0.1 ppm), which is a reference value for candy.
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Peru / Produtos para Lábios / Chumbo País/Região como assunto: América do Sul / Peru Idioma: Espanhol Revista: Horiz. méd. (Impresa) Ano de publicação: 2014 Tipo de documento: Artigo Instituição/País de afiliação: Universidad de San Martín de Porres/PE
Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Peru / Produtos para Lábios / Chumbo País/Região como assunto: América do Sul / Peru Idioma: Espanhol Revista: Horiz. méd. (Impresa) Ano de publicação: 2014 Tipo de documento: Artigo Instituição/País de afiliação: Universidad de San Martín de Porres/PE
...