Your browser doesn't support javascript.
loading
Efectividad de la biometría de inmersión para el cálculo del poder dióptrico de la lente intraocular / Effectiveness of immersion biometry for the calculation of intraocular lens dioptric power
Montero Díaz, Eric; Serpa Valdés, Mayelín; Cuan Aguilar, Yoriel; Pérez Candelaria, Eneida de la C; Hernández López, Iván; Vidal del Castillo, Malvis.
Afiliação
  • Montero Díaz, Eric; Institutto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Serpa Valdés, Mayelín; Institutto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cuan Aguilar, Yoriel; Institutto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Pérez Candelaria, Eneida de la C; Institutto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Hernández López, Iván; Institutto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Vidal del Castillo, Malvis; Institutto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. oftalmol ; 27(3): 350-358, jul.-set. 2014. tab
Artigo em Espanhol | LILACS, CUMED | ID: lil-744014
Biblioteca responsável: CU1.1
RESUMEN
OBJETIVO: determinar la efectividad de la biometría de inmersión para el cálculo del lente intraocular. MÉTODOS: se realizó un estudio observacional descriptivo, prospectivo. El universo estuvo constituido por los pacientes operados de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer", entre enero y septiembre de 2011. La muestra estuvo conformada por 39 ojos de 34 pacientes que cumplieron con los criterios de inclusión establecidos para la investigación y fueron operados por la técnica de facoemulsificación con previo cálculo del lente intraocular por biometría de inmersión e interferometría de coherencia óptica. RESULTADOS: el promedio de edad fue de 72,33 años, con un predominio del sexo femenino. La diferencia de longitud axial promedio entre los pacientes calculados por inmersión y los de IOL Máster fue de 0,09 mm, mientras que la diferencia de profundidad de la cámara anterior fue de 0,19 mm. Se obtuvo una diferencia de 0,13 D y no existió diferencia significativa en cuanto al cálculo del poder del lente intraocular entre ambos métodos. CONCLUSIONES: los valores de longitud axial y de profundidad de cámara anterior obtenidos mediante biometría de inmersión pueden ser utilizados para calcular con efectividad el poder del lente intraocular de los pacientes que serán sometidos a cirugía de cataratas, lo que demuestra ser una alternativa en ausencia del IOL Máster.
ABSTRACT
OBJECTIVE: to characterize the functional capacity and the quality of life of the elderly people with macular degeneration and low vision who were seen at "Ramon Pando Ferrer" Cuban Institute of Ophthalmology from January to June 2013. METHODS: Cross-sectional and descriptive study that included the following variables: age, sex, race, best corrected near visual acuity using Zeiss chart before and after visual rehabilitation, visual disability, functional capacity for daily life activities, clinical type of macular degeneration, risk factors for the disease, reason for visual rehabilitation and prescribed optical and non-optical aids. RESULTS: the disease prevailed in females (55,2 %), 75-79 years-old age group and Caucasians. Predominant visual disability was mild to moderate low vision; the mostly found functional capacity was independence with some limitations. Dry macular degeneration was present in 82,7 % of cases; the most frequent risk factor was smoking (82,7 %); reading and writing was the main motivation and a large number of patients improved their visual acuity after rehabilitation. The optical and non-optical aids that were mostly prescribed included microscopes and lighting. CONCLUSIONS: females, 75-79 years-old age group and Caucasians are the risk factors that cause the highest number of cases with macular degeneration and low vision. Visual disability prevailed among those classified as mild to moderate low vision patients. Dry macular degeneration .
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: CUMED / LILACS Assunto principal: Extração de Catarata / Biometria / Facoemulsificação / Lentes Intraoculares Tipo de estudo: Estudo observacional / Fatores de risco Aspecto: Preferência do paciente Limite: Idoso / Feminino / Humanos Idioma: Espanhol Revista: Rev. cuba. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Institutto Cubano de Oftalmología Ramón Pando Ferrer/CU
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: CUMED / LILACS Assunto principal: Extração de Catarata / Biometria / Facoemulsificação / Lentes Intraoculares Tipo de estudo: Estudo observacional / Fatores de risco Aspecto: Preferência do paciente Limite: Idoso / Feminino / Humanos Idioma: Espanhol Revista: Rev. cuba. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Institutto Cubano de Oftalmología Ramón Pando Ferrer/CU
...