Rapid on-site cytopathological examination (ROSE) performed by endosonagraphers and its improvement in the diagnosis of pancreatic solid lesions
Ganc, Ricardo Leite; Carbonari, Augusto Pincke Cruz; Colaiacovo, Rogério; Araujo, Júlia; Filippi, Sheila; Silva, Rodrigo Altenfender; Pacheco Junior, Adhemar Monteiro; Rossini, Lucio Giovanni Battista; Giovannini, Marc.
Afiliação
  • Ganc, Ricardo Leite; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
  • Carbonari, Augusto Pincke Cruz; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
  • Colaiacovo, Rogério; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
  • Araujo, Júlia; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
  • Filippi, Sheila; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
  • Silva, Rodrigo Altenfender; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
  • Pacheco Junior, Adhemar Monteiro; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
  • Rossini, Lucio Giovanni Battista; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
  • Giovannini, Marc; Santa Casa de São Paulo. Faculdade de Ciências Médicas. Sao Paulo. BR
Acta cir. bras ; Acta cir. bras;30(7): 503-508, 07/2015. tab, graf
Article em En | LILACS | ID: lil-754980
Biblioteca responsável: BR1.1
ABSTRACT

PURPOSE:

To evaluate the diagnosis improvement of EUS-FNA when using ROSE performed by the endosonographer.

METHODS:

A retrospective study was conducted. A total of 48 pancreatic solid masses EUS-FNA were divided into two groups according to the availability of on-site cytology (ROSE) - the first 24 patients (group A-without ROSE) and the latter 24 cases (group B-with ROSE). Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, complications and inadequacy rate of EUS-FNA were determined and compared.

RESULTS:

Among the 48 EUS-FNA, the overall performance was sensitivity 82%; specificity 100%; positive predictive value (PPV) 100%; negative predictive value (NPV) 70% and accuracy 87%. The sensitivity of the Group A was 71%, versus 94% in-group B (p=0.61). Moreover, the negative predictive value was 58% versus 87% (p=0.72). The accuracy rate increased from 79% to 96% (p=0.67) in the ROSE group. The number of punctures was similar between the groups. No major complications were reported.

CONCLUSION:

Rapid on-site cytopathological examination, even when performed by the endosonographer, may improve the diagnostic performance in the diagnosis of solid pancreatic lesions, regardless of the slight increase in the number of punctures. .
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Pâncreas / Pancreatopatias / Endossonografia / Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Acta cir. bras Assunto da revista: Cirurgia Geral / Procedimentos Cir£rgicos Operat¢rios Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Pâncreas / Pancreatopatias / Endossonografia / Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Acta cir. bras Assunto da revista: Cirurgia Geral / Procedimentos Cir£rgicos Operat¢rios Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil