RESUMO
Este estudo comparou duas diferentes máquinas de ensaio mecânico (Shimadzu e Kratos), com ou sem a realização da termociclagem, na leitura da resistência adesiva ao cisalhamento (RAC) e do índice de adesivo remanescente (IAR) após a descolagem de bráquetes metálicos colados com resina Transbond XT. Foram utilizados 60 pré-molares humanos, nos quais foram colados bráquetes metálicos, divididos aleatoriamente em dois grupos Grupo I – com termociclagem (500 ciclos) entre 5º e 55ºC e Grupo II – sem termociclagem. Estes grupos foram subdivididos em quatro subgrupos (n=15). Foi realizado o teste mecânico de cisalhamento com ambas as máquinas subgrupos I A (Shimadzu) e I B (Kratos) e subgrupos II A (Shimadzu) e II B (Kratos). As amostras foram submetidas aos ensaios mecânicos de cisalhamento com velocidade de carga de 0,5 mm/min. Os resultados da RAC foram submetidos ao teste de normalidade de D’Agostino & Pearson, ANOVA - 1 Critério (a = 0,05), pós-teste de Tukey e os dados do IAR ao teste de Kruskal-Wallis (a = 0,05). Não foram encontradas diferenças estatisticamente significativas entre os subgrupos. Conclui-se que a utilização de diferentes tipos de máquinas de ensaio, com ou sem termociclagem, não apresentam diferenças estatísticas na leitura da resistência ao cisalhamento ou do índice de adesivo remanescente...
ABSTRACT
This study has compared two different mechanical testing machine (Shimadzu and Kratos), with or without performing of thermocycling, the reading of the adhesive shear strength (RAC) and the adhesive remnant index (ARI), after debonding of metal brackets bonded with Transbond XT resin. Metal brackets were bonded on sixty human premolars that were then randomly divided into two groups Group I - with thermocycling (500 cycles) between 5 and 55ºC and Group II - without thermocycling. These groups were divided into four subgroups (n = 15). Test was performed with both mechanical shearing machines subgroups I A (Shimadzu) and I B (Kratos) and subgroups II A (Shimadzu) and II B (Kratos). Samples were submitted to shear bond strength (SBS) testing with a crosshead speed of 0.5 mm/min. The results of the SBS were tested for normality D’Agostino & Pearson, test 1 way ANOVA (a = 0.05), Tukey post-test. Data from the ARI were submitted to the Kruskal-Wallis test (a = 0.05). There was no statistically significant difference between subgroups. There was no statistically significant difference between subgroups. It was concluded that the use of different types of test machines, with or without thermocycling did not show statistical differences in reading shear bond strength or adhesive remnant index...
Assuntos

Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Braquetes Ortodônticos / Remoção / Esmalte Dentário / Resistência ao Cisalhamento Tipo de estudo: Ensaio clínico controlado Limite: Adolescente / Criança / Humanos Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Assunto da revista: Odontologia / Ortodontia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UEPG/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Braquetes Ortodônticos / Remoção / Esmalte Dentário / Resistência ao Cisalhamento Tipo de estudo: Ensaio clínico controlado Limite: Adolescente / Criança / Humanos Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Assunto da revista: Odontologia / Ortodontia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UEPG/BR
...