Cobre antimicrobiano contra patógenos intrahospitalarios en Perú / Antimicrobial copper against nosocomial pathogens in Peru
Neciosup, Edwin; Vergara, Martha; Pairazamán, Omar; Apablaza, Marcos; Esparza, Mario.
Afiliação
  • Neciosup, Edwin; Universidad Nacional Pedro Ruiz Gallo. Lambayeque. PE
  • Vergara, Martha; Universidad Nacional Pedro Ruiz Gallo. Lambayeque. PE
  • Pairazamán, Omar; Universidad de Antofagasta. Facultad de Ciencias del Mar y Recursos Biológicos. Departamento de Biotecnología. Antofagasta. CL
  • Apablaza, Marcos; Universidad de Antofagasta. Facultad de Ciencias del Mar y Recursos Biológicos. Departamento de Biotecnología. Antofagasta. CL
  • Esparza, Mario; Universidad de Antofagasta. Facultad de Ciencias del Mar y Recursos Biológicos. Departamento de Biotecnología. Antofagasta. CL
An. Fac. Med. (Perú) ; 76(1): 9-13, ene.-mar. 2015. tab, graf
Artigo em Espanhol | LILACS, LIPECS | ID: lil-780431
Biblioteca responsável: PE13.1
RESUMEN
Las infecciones intrahospitalarias (IIH) constituyen un problema de salud pública que generan grandes gastos por parte de los gobiernos, debido a que los patógenos causantes de IIH presentan resistencia a fármacos y generan una mayor permanencia de los pacientes, pues la infraestructura hospitalaria constituye un reservorio favorable para los patógenos. Las superficies de cobre surgen como opción sanitaria y efectiva para controlar el crecimiento y propagación de estos patógenos.

Objetivos:

Evaluar la actividad bactericida de las superficies de cobre contra los principales bacterias patógenas causantes de IIH (Escherichia coli, Pseudomonas aeruginosa y Staphylococcus aureus).

Diseño:

Estudio experimental con muestreo no probabilístico. Lugar Hospital Regional Docente las Mercedes (HRDLM) y Hospital Provincial Docente Belén (HPDB), Lambayeque, Perú. Materiales Nueve cepas bacterianas, 3 de E. coli, 3 de P. aeruginosa y 3 de S. aureus; superficies metálicas (1 cm2) de cobre y acero inoxidable (control). Intervenciones Las 9 cepas bacterianas fueron proporcionadas por los hospitales HRDLM (4 cepas) y HPDB (5 cepas). Los análisis de ANOVA y de Tukey fueron aplicados para evaluar la actividad bactericida de las superficies de cobre y acero inoxidable contra las 9 cepas causantes de IIH, usando los programas estadísticos Minitab y Sigmaplot, respectivamente. Principales medidas de

resultados:

Diferencias en el crecimiento bacteriano sobre superficies de cobre o acero inoxidable, con respecto al tiempo de exposición.

Resultados:

Las 9 cepas -3 de P. aeruginosa, 3 de E. coli y 3 de S. aureus- expuestas a superficies de cobre fueron eliminadas en 10, 15 y 60 minutos, respectivamente. La carga bacteriana de las células expuestas en superficies de acero inoxidable permaneció constante y viable por periodos mayores a 60 minutos. Además, las superficies de cobre eliminaron más rápido a las bacterias Gram negativas (P. aeruginosa y E. coli) con respecto...
ABSTRACT
Nosocomial infections (NI) generate large expenditures by governments, as NI pathogens are resistant to drugs and increase hospital stay. Copper surfaces seem a promising alternative to control growth and spread of these pathogens.

Objectives:

To evaluate copper surfaces bactericidal activity against pathogenic bacteria causing NI (E. coli, P. aeruginosa and S. aureus).

Design:

Experimental study with non-probability sampling. Institutions Hospital Regional Docente las Mercedes (HRDLM) and Hospital Provincial Docente Belen (HPDB), Lambayeque, Peru. Materials Nine bacterial strains of E. coli, P. aeruginosa and S. aureus, metal surfaces (1 cm2) of copper and stainless steel (control).

Interventions:

Bacterial strains were provided by HRDLM (4 strains) and HPDB (5 strains). ANOVA and Tukey analysis were applied to evaluate copper and stainless steel surfacesÆ bactericidal activity to strains causing NI; Minitab statistical software and Sigmaplot were used. Main outcome

measures:

Differences in bacterial growth on metal surfaces (copper or stainless steel) with respect to exposure time.

Results:

The nine strains of P. aeruginosa (3), E. coli (3) and S. aureus (3) exposed to copper surfaces were inactivated after 10, 15, and 60 minutes respectively. The bacterial load of cells exposed to stainless steel surfaces remained constant and viable for periods longer than 60 minutes. Copper surfaces removed Gram-negative bacteria (E. coli and P. aeruginosa) faster than Gram-positive bacteria (S. aureus).

Conclusions:

Copper surfaces completely eliminated studied nosocomial bacteria. Thus they could replace steel as contact surfaces in Peruvian health facilities with high incidence of NI...
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Reservatórios de Doenças / Infecção Hospitalar / Cobre / Planejamento Hospitalar / Antibacterianos Limite: Humanos País/Região como assunto: América do Sul / Peru Idioma: Espanhol Revista: An. Fac. Med. (Perú) Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Nacional Pedro Ruiz Gallo/PE / Universidad de Antofagasta/CL

Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Reservatórios de Doenças / Infecção Hospitalar / Cobre / Planejamento Hospitalar / Antibacterianos Limite: Humanos País/Região como assunto: América do Sul / Peru Idioma: Espanhol Revista: An. Fac. Med. (Perú) Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Nacional Pedro Ruiz Gallo/PE / Universidad de Antofagasta/CL
...