Your browser doesn't support javascript.
loading
Estudo comparativo entre eletrogoniometria e fotogrametria digital / Comparative study between electrogoniometry and digital photogrammetry
Souza, Thiago Melo Malheiros de; Nóbrega Júnior, José Carlos Nogueira; Rodrigues, Diego Alves; Carvalho, Luis Carlos; Santos, Heleodório Honorato dos; Alencar, Jerônimo Farias; Ferreira, José Jamacy de Almeida.
Afiliação
  • Souza, Thiago Melo Malheiros de; Universidade Federal da Paraíba. João Pessoa. BR
  • Nóbrega Júnior, José Carlos Nogueira; Universidade Federal da Paraíba. João Pessoa. BR
  • Rodrigues, Diego Alves; Universidade Federal da Paraíba. João Pessoa. BR
  • Carvalho, Luis Carlos; Centro Universitário de João Pessoa. BR
  • Santos, Heleodório Honorato dos; Universidade Federal da Paraíba. Departamento de Fisioterapia. João Pessoa. BR
  • Alencar, Jerônimo Farias; Universidade Federal da Paraíba. Departamento de Fisioterapia. João Pessoa. BR
  • Ferreira, José Jamacy de Almeida; Universidade Federal da Paraíba. Departamento de Fisioterapia. João Pessoa. BR
Rev. bras. ciênc. saúde ; 17(2): 133-138, 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-786200
Biblioteca responsável: BR8.1
RESUMO
Objetivo: Avaliar a replicabilidade da fotogrametria digital emrelação à eletrogoniometria no movimento de flexão docotovelo. Material e Métodos: A amostra constituiu-se de 20sujeitos (8 homens, 12 mulheres; 20,1 ± 1,7 anos; 60,9 ± 9,3kg e 169 ± 8,8 cm), saudáveis, ativos, submetidos aeletrogoniometria e fotogrametria digital. Os sujeitos foramposicionados sentados, com o membro superior direitoapoiado em uma mesa, ombro fletido a 90° e antebraçosupinado. O ângulo de flexão do cotovelo foi medido com esem fixação do eletrogoniômetro, em três diferentes posições(fechado, intermediário e aberto) de forma aleatória,utilizando-se um goniômetro manual (CARCI) adaptado comum potenciômetro linear e uma câmera digital (Sony, DSCS750),e posteriormente processados nos softwares BioMede Fisio Office 2010, respectivamente. Os dados foramanalisados no Statistical Package of Social Science (SPSS– 15.0), pelo teste de correlação intraclasse (ICC) para avaliara reprodutibilidade das medidas da eletrogoniometria efotogrametria inter-avaliadores e inter-instrumentos.Resultados: Observou-se forte reprodutibilidade dafotogrametria em todas as medidas, inter-avaliadores(ICC>0,85; P<0,01) e inter-instrumentos (ICC>0,93; P<0,01).Conclusão: Os resultados deste estudo permitem concluirque a fotogrametria digital possui alto índice de confiabilidade,tanto inter-avaliadores quanto inter-instrumentos e, portanto,pode ser utilizada na prática fisioterapêutica.
ABSTRACT
Objective: To evaluate the digital photogrammetry replicabilitycompared to electrogoniometry on the elbow flexionmovement. Material and Methods: The sample wascomposed by 20 healthy and active subjects (8 men and 12women; 20.1 ± 1.7 years; 60.9 ± 9.3 kg and 169.0 ± 8.8 cm),submitted to electrogoniometry and digital photogrammetry.The subjects were in sitting position with the right arm restingon a table; the shoulder was flexed at 90 degrees with asupinated forearm. The elbow flexion angle was measuredwith and without fixing the electrogoniometer in three differentpositions (closed, intermediate, open) randomly, using amanual goniometer (CARCI) adapted with a linearpotentiometer and a digital camera (Sony, DSC-S750), andsubsequently processed in the Biomed and Fisio Officesoftwares, respectively. Data were analyzed on the StatisticalPackage for Social Science (SPSS – 15.0) using the intraclasscorrelation (ICC) test to evaluate the reproducibility ofthe electrogoniometry and photogrammetry measures, interevaluatorsand inter-instruments. Results: It was observeda strong reproducibility of the electrogoniometry andphotogrammetry for all measures, inter-evaluators (ICC>0.85;P<0.01) and inter-instruments (ICC>0.93; P<0.01).Conclusion: The results of this study showed that the digitalphotogrammetry has high levels of reliability, both interevaluatorsand inter-instruments and thus can be used forphysical therapy practice.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Fotogrametria / Amplitude de Movimento Articular / Artrometria Articular Tipo de estudo: Ensaio clínico controlado / Guia de prática clínica Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. ciênc. saúde Assunto da revista: Medicina Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário de João Pessoa/BR / Universidade Federal da Paraíba/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Fotogrametria / Amplitude de Movimento Articular / Artrometria Articular Tipo de estudo: Ensaio clínico controlado / Guia de prática clínica Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. ciênc. saúde Assunto da revista: Medicina Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário de João Pessoa/BR / Universidade Federal da Paraíba/BR
...