Estudo comparativo entre teleradiografias de perfil escaneadas e fotografadas para uso no software Dolphin Imaging / A Comparison of Scanned and Corresponding Photographed Cephalograms For Use in Dolphin Imaging Software
Rev. cir. traumatol. buco-maxilo-fac
; 14(1): 91-95, Jan.-Mar. 2014. ilus, tab
Artigo
em Português
| LILACS, BBO - Odontologia
| ID: lil-792321
Biblioteca responsável:
BR310.1
Localização: BR310.1
RESUMO
O objetivo deste estudo foi comparar teleradiografias de perfil escaneadas e fotografadas para uso no Software Dolphin Imaging. Dez teleradiografias de perfil foram fotografadas para uso nesse programa computacional. Medidas lineares e angulares foram traçadas cefalometricamente e analisadas. Cada traçado foi repetido, duas vezes, no intervalo de 1 semana, pelo mesmo operador. As medidas foram tabladas no Microsoft Excel, e os testes t de Student e Wilcoxon foram utilizados para comparar cada medida. O coeficiente de correlação intraclasse foi utilizado para se verificar a padronização intraexaminador, e os resultados >0.92 indicavam alta confiabilidade. Nenhuma diferença estatisticamente significante foi observada entre os 2 grupos em todas as medidas lineares e angulares. Pode-se concluir, então, que ambos os métodos (fotografias e scanner) podem ser realizados para a utilização no Software Dolphin Imaging... (AU)
ABSTRACT
The purpose of this study was to compare scanned cephalograms to photographed cephalograms for use in Dolphin Imaging Software. Ten lateral cephalograms were photographed and scanned to be used in Dolphin Imaging Software. Linear and angular measurements were tracing and analyzed. Each tracing was repeated twice with 1-week interval, by the same operator. The measures were tabulated at Microsoft Excel and Students-t and Wilcoxon tests were used to compare each measurement. The intraclass correlator coefficient was used to test the intraexaminer reability and was >0.92 and it featured a high reability. No statistically difference was observed between the two groups, in all of the linear and angular measurements. We concluded that for the use in the Dolphin Imaging Software both methods (photographs and scanner) can be used... (AU)
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
BBO - Odontologia
/
LILACS
Assunto principal:
Validação de Programas de Computador
/
Cefalometria
/
Cirurgia Ortognática
Limite:
Humanos
Idioma:
Português
Revista:
Rev. cir. traumatol. buco-maxilo-fac
Assunto da revista:
Odontologia
Ano de publicação:
2014
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Universidade Estadual Paulista/BR
/
Universidade Estadual de Campinas/BR