Your browser doesn't support javascript.
loading
Use of mean platelet component to measure platelet activation on the ADVIA 120 haematology system.
Macey, M G; Carty, E; Webb, L; Chapman, E S; Zelmanovic, D; Okrongly, D; Rampton, D S; Newland, A C.
Afiliação
  • Macey MG; Department of Haematology, The Royal London Hospital, London, United Kingdom. M.G.Macey@mds.qmw.ac.uk
Cytometry ; 38(5): 250-5, 1999 Oct 15.
Article em En | MEDLINE | ID: mdl-10516612
ABSTRACT
Platelet activation results in changes in a number of cell surface molecules including an increase in P-Selectin (CD62P) that may be rapidly and conveniently measured by immunofluorescent flow cytometry. The ADVIA 120 (Bayer) is a new system that facilitates more accurate measurement of platelet volume and in addition provides an approximate measure of the mean refractive index (RI) of the platelets reported as mean platelet component (MPC) concentration. We were interested to determine whether changes in MPC might reflect changes in platelet activation status. To investigate this, the platelet CD62P expression, determined by flow cytometry, and change in MPC, measured on the ADVIA 120 system, was first examined in vitro after stimulation of EDTA anticoagulated whole blood with submaximal concentrations of bovine thrombin in the presence or absence of the thromboxane synthase inhibitor, Ridogrel. Thrombin produced a dose-dependent increase in platelet CD62P expression and a decrease in MPC that could be inhibited by Ridogrel at physiological concentrations. In the second set of experiments, blood from 20 normal controls was collected into both EDTA and sodium citrate (SC) anticoagulants. Within 30 min of venesection and again at 3 h post-venesection after storage at room temperature, the platelet MPC and CD62P expression were determined. Platelets in all samples with both anticoagulants showed very low levels of CD62P expression when first analysed. At 3 h there was a small increase in CD62P expression on platelets in whole blood anticoagulated with SC, but a significant (P < 0.001) increase was observed on platelets anti-coagulated with EDTA. A negative correlation was found between the change in MPC of the platelets and the increase in the mean fluorescence intensity (MFI) (r = -0.69, P < 0.001, n = 20) and the percentage (r = -0.72, P < 0.001, n = 20) of CD62P positive platelets at 3 h in blood anticoagulated with EDTA. We conclude that a reduction in MPC as measured by the ADVIA 120 may be used to detect anticoagulant induced, as well as thrombin stimulated, in vitro platelet activation in blood anticoagulated with EDTA. Further, we conclude that platelet activation is negligible for up to 3 h in sodium citrate anticoagulated whole blood.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contagem de Plaquetas / Plaquetas / Ativação Plaquetária / Selectina-P Limite: Adult / Animals / Humans Idioma: En Revista: Cytometry Ano de publicação: 1999 Tipo de documento: Article País de afiliação: Reino Unido
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contagem de Plaquetas / Plaquetas / Ativação Plaquetária / Selectina-P Limite: Adult / Animals / Humans Idioma: En Revista: Cytometry Ano de publicação: 1999 Tipo de documento: Article País de afiliação: Reino Unido
...