Analysis of light noise sources in a recycled Michelson interferometer with Fabry-Perot arms.
Camp, J B; Yamamoto, H; Whitcomb, S E; McClelland, D E.
Afiliação
  • Camp JB; LIGO Project, California Institute of Technology, Pasadena 91125, USA. jordan@ligo.caltech.edu
J Opt Soc Am A Opt Image Sci Vis ; 17(1): 120-8, 2000 Jan.
Article em En | MEDLINE | ID: mdl-10641846
We present a method by which the effect of laser field variations on the signal output of an interferometric gravitational wave detector is rigorously determined. Using the Laser Interferometer Gravitational Wave Observatory (LIGO) optical configuration of a power recycled Michelson interferometer with Fabry-Perot arm cavities as an example, we calculate the excess noise after the input filter cavity (mode cleaner) and the dependence of the detector strain sensitivity on laser frequency and amplitude noise, radio frequency oscillator noise, and scattered-light phase noise. We find that noise on the radio frequency sidebands generally limits the detector's sensitivity.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Interferometria / Luz / Modelos Teóricos Idioma: En Revista: J Opt Soc Am A Opt Image Sci Vis Assunto da revista: OFTALMOLOGIA Ano de publicação: 2000 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Interferometria / Luz / Modelos Teóricos Idioma: En Revista: J Opt Soc Am A Opt Image Sci Vis Assunto da revista: OFTALMOLOGIA Ano de publicação: 2000 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos