Your browser doesn't support javascript.
loading
Assessment of indoor fine aerosol contributions from environmental tobacco smoke and cooking with a portable nephelometer.
Brauer, M; Hirtle, R; Lang, B; Ott, W.
Afiliação
  • Brauer M; The University of British Columbia, School of Occupational and Environmental Hygiene, Vancouver, Canada. brauer@interchange.ubc.ca
J Expo Anal Environ Epidemiol ; 10(2): 136-44, 2000.
Article em En | MEDLINE | ID: mdl-10791595
ABSTRACT
Personal monitoring studies have indicated that environmental tobacco smoke (ETS) and cooking are major indoor particulate sources in residential and nonindustrial environments. Continuous monitoring of fine particles improves exposure assessment by characterizing the effect of time-varying indoor sources. We evaluated a portable nephelometer as a continuous monitor of indoor particulate levels. Simultaneous sampling with the nephelometer and PM2.5 impactors was undertaken to determine the relationship between particle light scattering extinction coefficient (sigma(sp)) and particle mass concentration in field and environmental chamber settings. Chamber studies evaluated nephelometer measurements of ETS and particles produced from toasting bread and frying foods. Field measurements were conducted in 20 restaurants and bars with different smoking restrictions, and in five residential kitchens. Additional measurements compared the nephelometer to a different mass measurement method, a piezobalance, in a well-characterized residence where various foods were cooked and ETS was produced. Since the piezobalance provides 2-min average mass concentration measurements, these comparisons tested the ability of the nephelometer to measure transient particle concentration peaks and decay rate curves. We found that sigma(sp) and particle mass were highly correlated (R2 values of 0.63-0.98) over a large concentration range (5-1600 microg/m3) and for different particle sources. Piezobalance and gravimetric comparisons with the nephelometer indicated similar sigma(sp) vs. mass slopes (5.6 and 4.7 m2/g for piezobalance and gravimetric comparisons of ETS, respectively). Somewhat different sigma(sp) vs. particle mass slopes (1.9-5.6 m2/g) were observed for the different particle sources, reflecting the influence of particle composition on light scattering. However, in similar indoor environments, the relationship between particle light scattering and mass concentration was consistent enough to use independent nephelometer measurements as estimates of short-term mass concentrations. A method to use nephelometer measurements to determine particulate source strengths is derived and an example application is described.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição por Fumaça de Tabaco / Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Culinária Limite: Humans Idioma: En Revista: J Expo Anal Environ Epidemiol Assunto da revista: EPIDEMIOLOGIA / SAUDE AMBIENTAL Ano de publicação: 2000 Tipo de documento: Article País de afiliação: Canadá
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição por Fumaça de Tabaco / Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Culinária Limite: Humans Idioma: En Revista: J Expo Anal Environ Epidemiol Assunto da revista: EPIDEMIOLOGIA / SAUDE AMBIENTAL Ano de publicação: 2000 Tipo de documento: Article País de afiliação: Canadá