Your browser doesn't support javascript.
loading
WBC reduction in RBC concentrates by prestorage filtration: multicenter experience.
Yomtovian, R; Gernsheimer, T; Assmann, S F; Mohandas, K; Lee, T H; Kalish, L A; Busch, M P.
Afiliação
  • Yomtovian R; Blood Bank-Transfusion Medicine Service, University Hospitals of Cleveland, Cleveland, Ohio 44106, USA. ryomtovian@yahoo.com
Transfusion ; 41(8): 1030-6, 2001 Aug.
Article em En | MEDLINE | ID: mdl-11493735
ABSTRACT

BACKGROUND:

As universal leukocyte (WBC) reduction (ULR) is being considered as a new standard, few data are available on the performance of WBC-reduction filtration in routine practice. The performance of WBC-reduction in RBCs, using varied filtration practices, in meeting the current FDA requirement (<5 x 10(6)), Council of Europe (EC) recommendation, the proposed FDA requirement (<1 x 10(6)), and a more stringent proposal (<5 x 10(5)) for residual WBCs per RBC unit was assessed and compared. STUDY DESIGN AND

METHODS:

Participating facilities were the 11 sites of the Viral Activation Transfusion Study (VATS), a prospective study of the impact of transfusion with and without WBC-reduction on survival and HIV viral load in HIV-1-infected patients. Patients randomly assigned to undergo WBC reduction were required to receive RBCs < or =14 days old that had undergone prestorage (within 72 hours of collection) WBC-reduction filtration by a method devised to achieve a postfiltration WBC count of <5 x 10(6). Residual WBC quantitation was performed by PCR in the central VATS laboratory by using frozen WBC-reduced RBC samples obtained at issue for transfusion.

RESULTS:

A total of 1869 WBC-reduced RBC units were studied. Filtration practices varied within and between sites. There were significant differences in mean residual WBC counts at the 11 sites (p<0.001). Among the WBC-reduced RBC units, 0.8 percent exceeded 5 x 10(6) WBCs per unit, 8.3 percent exceeded 1 x 10(6) WBCs per unit, and 14.3 percent exceeded 5 x 10(5) WBCs per unit.

CONCLUSION:

Residual WBCs in WBC-reduced RBC units vary within and between sites. WBC reduction was successful, in that over 99 percent and 91 percent of VATS WBC-reduced RBC units met US and EC thresholds, respectively. However, the small but measurable failure rate indicates that not every unit will meet these guidelines.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Remoção de Componentes Sanguíneos / Transfusão de Eritrócitos / Leucócitos Tipo de estudo: Clinical_trials / Guideline / Observational_studies Limite: Humans Idioma: En Revista: Transfusion Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Remoção de Componentes Sanguíneos / Transfusão de Eritrócitos / Leucócitos Tipo de estudo: Clinical_trials / Guideline / Observational_studies Limite: Humans Idioma: En Revista: Transfusion Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Estados Unidos