Comparison of axial reconstructed ultrasonographic images from three-dimensional data volumes and computed tomographic scans in the documentation and detection of liver lesions.
Beissert, M; Jenett, M; Kessler, C; Keberle, M; Jahns, R; Hahn, D.
Afiliação
  • Beissert M; Department of Radiology, University of Wurzburg, Germany.
J Ultrasound Med ; 20(9): 953-7, 2001 Sep.
Article em En | MEDLINE | ID: mdl-11549154
ABSTRACT

OBJECTIVE:

To compare axial reconstructed ultrasonographic images from three-dimensional data volumes and conventional computed tomographic scans in documentation and detection of liver lesions.

METHODS:

The livers of 23 patients were examined by a multifrequency curved array transducer to acquire three-dimensional data volumes and by conventional computed tomography The ultrasonographic device was equipped with three-dimensional ultrasonographic technology allowing for real-time parallel movement in every plane within an acquired data volume. Axial ultrasonographic images reconstructed from three-dimensional data volumes were compared with conventional computed tomographic scans.

RESULTS:

When both methods were taken together, a total of 51 different liver lesions could be detected. Reconstructed ultrasonographic images depicted 44 (86%) of 51 lesions, and computed tomographic scans showed 46 (90%) of 51 lesions. Compared with computed tomography, ultrasonography depicted 5 additional lesions in 3 of the patients (4 hemagiomas and 1 unspecified lesion), whereas 7 lesions were missed in another 4 patients (4 metastases, 2 calcifications, and 1 cyst). The Pearson correlation coefficient between ultrasonography and computed tomography was r = 0.84 (P < .001).

CONCLUSIONS:

Our study shows that ultrasonographic images can be effectively reconstructed from three-dimensional data volumes. With respect to documentation and detection of liver lesions, the results obtained by three-dimensional ultrasonography appear comparable with those obtained by conventional computed tomography. However, several technical and procedural limitations have to be respected.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Imageamento Tridimensional / Hepatopatias Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Imageamento Tridimensional / Hepatopatias Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Alemanha