Your browser doesn't support javascript.
loading
Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel.
Selby, J B; Johnson, D L; Hester, P; Caborn, D N.
Afiliação
  • Selby JB; University of Kentucky School of Medicine, Lexington 40536-0284, USA.
Am J Sports Med ; 29(5): 614-9, 2001.
Article em En | MEDLINE | ID: mdl-11573920
ABSTRACT
Initial tibial fixation strength is the weak link after anterior cruciate ligament reconstruction with a quadrupled hamstring tendon graft fixed with bioabsorbable interference screws. The purpose of this study was to determine the biomechanical differences between 28-mm and tapered 35-mm interference screws for tibial fixation of a soft tissue graft in 16 young cadaveric tibias. Failure mode, displacement before failure, and ultimate failure load were tested with a testing machine aligned with the tibial tunnel to simulate a worst-case scenario. The mode of failure was graft slippage past the screw in all but one of the specimens. The mean maximum load at failure of the 28-mm screw was 594.9 +/- 141.0 N, with mean displacement at failure of 10.97 +/- 2.20 mm. The mean maximum load at failure of the 35-mm screw was 824.9 +/- 124.3 N, with a mean displacement to failure of 14.38 +/- 2.15 mm. The 38% difference in mean maximal load at failure was significant. Important variables in hamstring tendon graft fixation within a bone tunnel include bone mineral density, dilatation, gap size, screw placement, and screw width and length. Attention to these variables will help to provide secure graft fixation during biologic incorporation throughout the rehabilitation period.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tíbia / Parafusos Ósseos / Ligamento Cruzado Anterior / Implantes Absorvíveis Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Middle aged Idioma: En Revista: Am J Sports Med Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tíbia / Parafusos Ósseos / Ligamento Cruzado Anterior / Implantes Absorvíveis Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Middle aged Idioma: En Revista: Am J Sports Med Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Estados Unidos
...