Comparison of advanced oxidation processes in flow-through pilot plants (part I).
Muller, J P; Jekel, M.
Afiliação
  • Muller JP; Department of Water Quality Control, Technical University of Berlin, Germany.
Water Sci Technol ; 44(5): 303-9, 2001.
Article em En | MEDLINE | ID: mdl-11695474
ABSTRACT
The advanced oxidation processes (AOPs) UV/H2O2, UV/O3 and O3/H2O2 were optimised to achieve a 90% degradation of the micropollutant atrazine in continuous-flow reactors. The experiments were performed with spiked Berlin tap-water. The comparison of mechanistically different oxidation systems needs a non-specific figure-of-merit to avoid influences by system-inherent parameters. The chosen figure-of-merit consists of the electrical energy per order of magnitude in oxidation per m3, EE/o. The combination O3/H2O2 proved to be the most efficient process by means of energy consumption.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxidantes Fotoquímicos / Ozônio / Atrazina / Oxidantes / Herbicidas / Peróxido de Hidrogênio Idioma: En Revista: Water Sci Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Alemanha País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxidantes Fotoquímicos / Ozônio / Atrazina / Oxidantes / Herbicidas / Peróxido de Hidrogênio Idioma: En Revista: Water Sci Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2001 Tipo de documento: Article País de afiliação: Alemanha País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM