Comparative analysis of pulpal circulatory reaction to an acetone-containing and an acetone-free bonding agent as measured by vitalmicroscopy.
Iványi, I; Balogh, A E; Fazekas, A; Rosivall, L; Nyárasdy, I.
Afiliação
  • Iványi I; Semmelweis University, Faculty of Dentistry, Department of Conservative Dentistry, Budapest, Hungary. ivanyi@konfog.sote.hu
Oper Dent ; 27(4): 367-72, 2002.
Article em En | MEDLINE | ID: mdl-12120774
Despite great progress in the production of new dental polymers, application of these products is still controversial. The unlined utilization of cytotoxic adhesive materials on pulpal dentin can adversely influence the pulp, leading to alterations in local microcirculation that can be an early sign of pathological changes. In a previous study by the authors, the effect of an acetone-free bondmaterial was examined on the vascular diameter of pulpal vessels by means of vitalmicroscopy. In this study, experiments comparing experimental data provided by an acetone-containing bondmaterial to these earlier findings with acetone-free ones have been performed. Thirty male Sprague-Dawley rats (weighing 333+/-9 g) were used for this investigation. The first lower incisor was prepared for vitalmicroscopy. Changes in vessel diameter were recorded prior to and 5, 15, 30 and 60 minutes after the investigated materials (Scotchbond Multi-Purpose Dental Adhesive System or Prime & Bond 2.1) were administered on dentin as recommended by the manufacturer. In control rats (saline administration), the vessel diameter was stable during the experiment. In the presence of acetone-free bondmaterial (Scotchbond), the vessel diameter was increased during the experimental period in relation to the baseline (12.15+/-2.85%; 16.36+/-2.39%; 14.16+/-3.48%; 12.12+/-3.72%). In the presence of acetone-containing bondmaterial (Prime & Bond 2.1), a similar result was observed (10.56+/-2.27%; 16.13+/-2.94%; 17.88+/-2.54%; 14.54+/-3.16%). The differences between the control values and those registered with test groups were significant (p<0.05; ANOVA). There was no significant difference among the test groups. The results of this study suggest that dental bond materials applied on a very thin layer of dentin may affect the blood supply to the dental pulp. However, no stasis or prestasis has been detected, indicating a possible reversible effect. The authors could not show any statistical difference between the vasodilatation caused by the acetone-containing and the acetone-free bond material.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acetona / Adesivos Dentinários / Polpa Dentária Limite: Animals Idioma: En Revista: Oper Dent Ano de publicação: 2002 Tipo de documento: Article País de afiliação: Hungria País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acetona / Adesivos Dentinários / Polpa Dentária Limite: Animals Idioma: En Revista: Oper Dent Ano de publicação: 2002 Tipo de documento: Article País de afiliação: Hungria País de publicação: Estados Unidos