Your browser doesn't support javascript.
loading
Chiral separation of bupivacaine enantiomers by capillary electrophoresis partial-filling technique with human serum albumin as chiral selector.
Martínez-Pla, J J; Martín-Biosca, Y; Sagrado, S; Villanueva-Camañas, R M; Medina-Hernández, M J.
Afiliação
  • Martínez-Pla JJ; Departamento de Química Analítica, Facultat de Farmacia, Universitat de Valencia, C/Vicent Andrés Estellés s/n, E-46100 Burjassot, Valencia, Spain.
J Chromatogr A ; 1048(1): 111-8, 2004 Sep 03.
Article em En | MEDLINE | ID: mdl-15453425
Capillary electrophoresis (CE) is a powerful technique for enantiomer separations due to its intrinsic high separation efficiencies, speed of analysis, low reagent consumption and small sample requirements. However, some chiral selectors present strong background UV absorption providing high detection limits. The present paper deals with the application of the partial-filling technique to the separation of bupivacaine enantiomers by capillary electrophoresis using human serum albumin (HSA) as chiral selector. In this procedure the cationic surfactant cetyltrimethylammonium bromide (CTAB) was used as a dinamic capillary coating in order to reduce the electro-osmotic flow and detect both bupivacaine enantiomers out of the chiral selector plug. Several experimental conditions such as CTAB concentration, pH, HSA concentration and plug length, background electrolyte concentration, temperature and voltage were studied. Under the selected conditions it is possible to detect the separated enantiomers out of the HSA plug in less than 4 min using 50 mM Tris pH 8 as background electrolyte with 50 microM CTAB, at 30 degrees C and using a separation voltage of 25 kV. The proposed methodology was then validated for analytical purposes and applied to the analysis of pharmaceutical preparations commercially available. The results obtained with the proposed methodology were in good agreement with those declared by the manufacturers. The simplicity, sample throughput, accuracy, reproducibility and low cost of the proposed method make it suitable for the control of the enantiomeric composition of bupivacaine in pharmaceuticals.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bupivacaína / Eletroforese Capilar / Anestésicos Locais Idioma: En Revista: J Chromatogr A Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Espanha País de publicação: Holanda
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bupivacaína / Eletroforese Capilar / Anestésicos Locais Idioma: En Revista: J Chromatogr A Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Espanha País de publicação: Holanda