Contrast-enhanced MR angiography at 1.5 T after implantation of platinum stents: in vitro and in vivo comparison with conventional stent designs.
Hagspiel, Klaus D; Leung, D A; Nandalur, Kiran R; Angle, John F; Dulai, Harjot S; Spinosa, David J; Matsumoto, A H; Christopher, J M; Ahmed, Hossam; Berr, S S.
Afiliação
  • Hagspiel KD; Department of Radiology, Division of Interventional Radiology, University of Virginia Health System, Box 800170, Charlottesville, VA 22908, USA.
AJR Am J Roentgenol ; 184(1): 288-94, 2005 Jan.
Article em En | MEDLINE | ID: mdl-15615990
OBJECTIVE: The objective of our study was to evaluate the in vitro and in vivo 3D contrast-enhanced MR angiography characteristics of a new platinum-based balloon-expandable stent system and compare this system with a variety of competing metallic stents. MATERIALS AND METHODS: All experiments were performed on 1.5-T scanners. In vitro experiments were performed using 10 stents implanted into a custom-built phantom. Different orientations of the stents along the magnetic field and multiple flip angles were examined. In addition, 19 patients underwent contrast-enhanced MR angiography after the implantation of 36 stents, including four patients with six platinum stents. Angiographic correlation was available for all 19 patients, and luminal patency and stent-induced artifacts were assessed quantitatively. RESULTS: Of the tested balloon-expandable stents, only the platinum-based stents created artifact causing luminal narrowing of 30% or less. All other balloon-expandable stents induced larger artifacts that resulted in higher degrees of narrowing. Thus, if patent, the platinum-based stents allow significant in-stent stenosis to be ruled out reliably. Selected nitinol- or tantalum-based self-expandable stents also are suitable in this regard. CONCLUSION: Of the tested devices, platinum-based stents are the only type of currently available balloon-expandable stent that creates 30% or less artifact-induced apparent stenosis and thus are suitable for MR angiography.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arteriopatias Oclusivas / Stents / Angiografia por Ressonância Magnética Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arteriopatias Oclusivas / Stents / Angiografia por Ressonância Magnética Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos