Your browser doesn't support javascript.
loading
Left ventricular ejection fraction calculation from automatically selected and processed diastolic and systolic frames in short-axis cine-MRI.
Lalande, Alain; Salvé, N; Comte, A; Jaulent, M C; Legrand, L; Walker, P M; Cottin, Y; Wolf, J E; Brunotte, F.
Afiliação
  • Lalande A; Laboratoire de Biophysique, Faculté de Médecine, Université de Bourgogne, Dijon Cedex, France. alalande@u-bourgogne.fr
J Cardiovasc Magn Reson ; 6(4): 817-27, 2004.
Article em En | MEDLINE | ID: mdl-15646885
The calculation of the left ventricular ejection fraction (LVEF) is dependent upon the accurate measurement of diastolic and systolic left ventricular volumes. Although breath-hold cine magnetic resonance imaging (MRI) allows coverage of the whole cardiac cycle with an excellent time resolution, many authors rely on the visual selection of diastolic and the systolic short-axis slices in order to reduce the postprocessing time. An automatic method was developed to detect the endocardial contour on each image, allowing an automatic selection of the systolic frame. The calculated ejection fraction was compared with radionuclide ventriculography (RNV). Sixty-five patients were examined using an electrocardiogram (ECG)-gated gradient echo sequence. Among these examinations, manual and automatic processing with MRI were compared when the time of the systolic frame concorded. Good correlations have been found between the automatic MRI approach and RNV, and between manual and automatic processing on MRI alone. The results show that the automatic determination of the ejection fraction is feasible, and should constitute an important step toward a larger acceptance of MRI as a routine tool in heart disease imaging. One major benefit of using automatic postprocessing is that it may eliminate the visual choice of the systolic frame, inaccurate in more than 50% of the studied patients.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Função Ventricular Esquerda / Imagem Cinética por Ressonância Magnética Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2004 Tipo de documento: Article País de afiliação: França País de publicação: Reino Unido
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Função Ventricular Esquerda / Imagem Cinética por Ressonância Magnética Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2004 Tipo de documento: Article País de afiliação: França País de publicação: Reino Unido