Your browser doesn't support javascript.
loading
Augmentation of abdominal organ perfusion during cardiopulmonary bypass with a novel intra-aortic pulsatile catheter pump.
Gu, Y J; De Kroon, T L; Elstrodt, J M; van Oeveren, W; Boonstra, P W; Rakhorst, G.
Afiliação
  • Gu YJ; Department of Biomedical Engineering, Groningen University Medical Center, The Netherlands. y.j.gu@med.rug.nl
Int J Artif Organs ; 28(1): 35-43, 2005 Jan.
Article em En | MEDLINE | ID: mdl-15742308
BACKGROUND: Current pulsatile pumps for cardiopulmonary bypass (CPB) are far from satisfactory because of the poor pulsatility. This study was undertaken to examine the efficiency of a novel pulsatile catheter pump on pulsatility and its effect on abdominal organ perfusion during CPB. METHODS: Twelve pigs weighing 89+/-11 kg were randomly divided into a pulsatile group (n=6) and a non-pulsatile group (n=6). All animals had a CPB for 120 min, aorta clamped for 60 min, temperature down to 32 degrees C, and a perfusion flow of 60 ml/kg/min. In the pulsatile group, a 21 Fr intra-aortic pulsatile catheter, which was connected to a 40 mL membrane pump, was placed in the descending aorta and activated by a balloon pump driver during the first 90 minutes of CPB until aortic declamping. Hemodynamics, organ blood flow, body metabolism, and blood trauma were studied during experiments. RESULTS: Compared with the non-pulsatile group during CPB, the pulsatile group had a higher systolic blood pressure (p<0.01), higher mean arterial pressure (p<0.05), and higher blood flow to the superior mesenteric artery (p<0.05). The hemodynamic energy, indicated by the energy equivalent pressure (EEP) was higher in the gastrointestinal tract and kidney in the pulsatile group (p<0.01, p<0.01). Abdominal organ perfusion status, as indicated by SvO 2 in the inferior vena cava, was higher in the pulsatile group (p<0.05) 30 min after cessation of CPB. Hemolysis indicated by release of free hemoglobin during CPB was similar in the two groups. CONCLUSION: Applying the pulsatile catheter pump in the descending aorta is effective in supplying the pulsatile flow to the abdominal organs and results in improved abdominal organ perfusion during the ischemic phase of CPB.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluxo Pulsátil / Vísceras / Ponte Cardiopulmonar / Abdome Limite: Animals Idioma: En Revista: Int J Artif Organs Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Holanda País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluxo Pulsátil / Vísceras / Ponte Cardiopulmonar / Abdome Limite: Animals Idioma: En Revista: Int J Artif Organs Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Holanda País de publicação: Estados Unidos