Your browser doesn't support javascript.
loading
Integration between point-of-care cardiac markers in an emergency/cardiology department and the central laboratory: methodological and preliminary clinical evaluation.
Di Serio, Francesca; Amodio, Gianfranco; Varraso, Lucia; Campaniello, Maurizio; Coluccia, Paola; Trerotoli, Paolo; Antonelli, Gianfranco; Pansini, Nicola.
Afiliação
  • Di Serio F; Unità Operativa di Patologia Clinica I, Policlinico di Bari, Bari, Italy. diseriofrancesca@tiscali.it
Clin Chem Lab Med ; 43(2): 202-9, 2005.
Article em En | MEDLINE | ID: mdl-15843218
To achieve rapid assessment of chest pain in emergency/cardiology departments, a short turnaround time for cardiac marker testing is necessary. Nevertheless, Total Quality Management principles must be incorporated into the management of point-of-care testing (POCT); in this setting we implemented the Stratus CS assay as POCT for cardiac markers in our emergency/cardiology department. The analytical performance of the troponin I method was evaluated; information connectivity between the Stratus CS data management system and the laboratory information system was implemented and practical training of testing personnel was carried out at the POCT site. A total of 41 non-ST-segment elevation patients admitted to the hospital were followed to evaluate the appropriateness of hospital admission, formulated on the basis of the cardiac troponin-I level measured at the POCT site by clinical staff. Our preliminary clinical data suggest that the high sensitivity of the Stratus CS troponin method could play an important role in the early identification of patients with acute myocardial infarction in a low to intermediate-risk population for acute coronary syndrome. Our POCT model suggests that the central laboratory could ensure that the POCT program remains in compliance with quality requirements. Nevertheless, our comparison studies suggest that the implementation of POCT requires a high level of integration between cardiologists and pathologists to guarantee appropriate interpretation of the monitoring results for suspected ACS patients.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistemas Automatizados de Assistência Junto ao Leito / Técnicas de Laboratório Clínico / Doença das Coronárias / Emergências Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Humans / Middle aged Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistemas Automatizados de Assistência Junto ao Leito / Técnicas de Laboratório Clínico / Doença das Coronárias / Emergências Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Humans / Middle aged Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha