Femoral neck fractures complicating metal-on-metal resurfaced hips: a report of 2 cases.
J Orthop Surg (Hong Kong)
; 13(1): 69-72, 2005 Apr.
Article
em En
| MEDLINE
| ID: mdl-15872404
ABSTRACT
Metal-on-metal hip resurfacing arthroplasty is increasingly popular for younger patients with advanced hip disease. Intra-operative or immediate postoperative femoral neck fracture after metal-on-metal hip resurfacing is a well-described technical complication, ranging from 0% to 1.5%. We report 2 cases of late femoral neck fracture occurring 8 and 15 months following the index operation, with a review of the literature. We recommend that patient selection should be of prime importance before embarking on metal-on-metal surface hip replacement to avoid such complications.